Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
246
matching recommendationsSIC | 3674 | Semiconductors And Related Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0335 # 04 Y:1998 | 04 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $310 | $0 | Implemented |
AS0203 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $861 | $570 | Implemented |
AS0203 # 08 Y:1997 | 08 | 1997 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $1,460 | $75 | Implemented |
AS0203 # 09 Y:1997 | 09 | 1997 | CONDENSE OPERATION INTO ONE BUILDING | $109,695 | $15,000 | Implemented |
MA0369 # 01 Y:1996 | 01 | 1996 | ADOPT IN-HOUSE MATERIAL GENERATION | $21,886 | $11,000 | Implemented |
MA0369 # 06 Y:1996 | 06 | 1996 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $919 | $0 | Implemented |
AS0183 # 03 Y:1996 | 03 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,440 | $20,000 | Implemented |
AS0183 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,906 | $2,211 | Implemented |
AS0183 # 05 Y:1996 | 05 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,348 | $0 | Implemented |
AS0183 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $2,105 | $1,200 | Implemented |
AS0183 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,873 | $11,962 | Implemented |
AS0184 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,415 | $7,000 | Implemented |
AS0184 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,108 | $1,750 | Implemented |
AS0184 # 04 Y:1996 | 04 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $21,398 | $25,000 | Implemented |
AS0184 # 05 Y:1996 | 05 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $15,892 | $35,000 | Implemented |
AS0184 # 08 Y:1996 | 08 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,954 | $4,163 | Implemented |
AS0184 # 11 Y:1996 | 11 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,847 | $54,958 | Implemented |
AS0184 # 14 Y:1996 | 14 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,827 | $1,200 | Implemented |
MA0366 # 02 Y:1996 | 02 | 1996 | OPTIMIZE PLANT POWER FACTOR | $11,369 | $9,450 | Implemented |
MA0366 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,474 | $350 | Implemented |
CO0349 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,640 | $54,100 | Implemented |
CO0349 # 02 Y:1995 | 02 | 1995 | RECOVER AND REUSE COOLING WATER | $18,410 | $2,190 | Implemented |
CO0349 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,690 | $7,000 | Implemented |
SF0066 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,169 | $722 | Implemented |
SF0066 # 03 Y:1995 | 03 | 1995 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,812 | $3,400 | Implemented |