Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

39

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0118 # 03 Y:1995 03 1995 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $202 $300 Implemented
CO0332 # 09 Y:1995 09 1995 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $280 $450 Implemented
UM0026 # 03 Y:1995 03 1995 INSTALL AUTOMATIC STACK DAMPER $855 $500 Not Implemented
ME0158 # 04 Y:1995 04 1995 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $5,257 $400 Not Implemented
AS0143 # 09 Y:1995 09 1995 ADJUST BURNERS FOR EFFICIENT OPERATION $1,479 $2,000 Implemented
GT0551 # 03 Y:1995 03 1995 INSTALL AUTOMATIC STACK DAMPER $50,375 $41,900 Implemented
AR0046 # 05 Y:1995 05 1995 ADJUST BURNERS FOR EFFICIENT OPERATION $1,569 $100 Implemented
NV0025 # 02 Y:1995 02 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $90,007 $29,278 Not Implemented
NV0023 # 04 Y:1995 04 1995 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $4,488 $1,600 Not Implemented
KU0452 # 05 Y:1995 05 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,286 $2,030 Not Implemented
OR0230 # 02 Y:1995 02 1995 ADJUST BURNERS FOR EFFICIENT OPERATION $660 $1,000 Implemented
UM0021 # 04 Y:1995 04 1995 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $28,057 $1,600 Not Implemented
UL0117 # 04 Y:1995 04 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,593 $1,146 Not Implemented
TN0537 # 01 Y:1995 01 1995 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $16,330 $2,190 Implemented