Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,018

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1602 # 06 Y:2016 06 2016 INSULATE BARE EQUIPMENT $618 $151 Not Implemented
UK1602 # 12 Y:2016 12 2016 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $23,450 $112,000 Not Implemented
MI0294 # 05 Y:2016 05 2016 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $5,921 $1,441 Implemented
SU0408 # 03 Y:2016 03 2016 INSULATE FEEDWATER TANK $48 $31 Implemented
SU0408 # 08 Y:2016 08 2016 INSULATE BARE EQUIPMENT $1,194 $2,183 Implemented
OK0935 # 03 Y:2016 03 2016 RECOVER WASTE HEAT FROM EQUIPMENT $4,052 $1,913 Not Implemented
OK0935 # 09 Y:2016 09 2016 COVER OPEN TANKS $8,035 $1,510 Not Implemented
NC0563 # 01 Y:2016 01 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,357 $3,050 Not Implemented
NC0563 # 09 Y:2016 09 2016 RECOVER WASTE HEAT FROM EQUIPMENT $212 $150 Not Implemented
MA0754 # 02 Y:2016 02 2016 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $112,215 $1,000 Not Implemented
MA0754 # 04 Y:2016 04 2016 INCREASE AMOUNT OF CONDENSATE RETURNED $62,104 $250,000 Not Implemented
OK0933 # 05 Y:2016 05 2016 INCREASE AMOUNT OF CONDENSATE RETURNED $24,062 $20,162 Implemented
OK0933 # 06 Y:2016 06 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,272 $3,404 Implemented
OK0933 # 07 Y:2016 07 2016 REPAIR AND ELIMINATE STEAM LEAKS $353 $240 Implemented
WV0522 # 02 Y:2016 02 2016 INSULATE BARE EQUIPMENT $3,281 $6,551 Not Implemented
LE0413 # 03 Y:2016 03 2016 RECOVER WASTE HEAT FROM EQUIPMENT $3,060 $1,800 Not Implemented
LE0413 # 07 Y:2016 07 2016 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,462 $25,000 Implemented
NC0562 # 03 Y:2016 03 2016 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $29,861 $3,000 Not Implemented
UD0944 # 01 Y:2016 01 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,720 $7,315 Not Implemented
UD0944 # 02 Y:2016 02 2016 INSULATE BARE EQUIPMENT $749 $2,640 Not Implemented
UD0944 # 03 Y:2016 03 2016 INSULATE BARE EQUIPMENT $476 $1,148 Not Implemented
WM0083 # 05 Y:2016 05 2016 INSULATE BARE EQUIPMENT $12,261 $1,680 Not Implemented
LE0414 # 02 Y:2016 02 2016 PREHEAT COMBUSTION AIR WITH WASTE HEAT $34,860 $36,000 Implemented
SD0525 # 02 Y:2016 02 2016 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,754 $16,450 Not Implemented
SD0525 # 08 Y:2016 08 2016 INSULATE BARE EQUIPMENT $1,494 $527 Not Implemented