Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,018
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1602 # 06 Y:2016 | 06 | 2016 | INSULATE BARE EQUIPMENT | $618 | $151 | Not Implemented |
UK1602 # 12 Y:2016 | 12 | 2016 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $23,450 | $112,000 | Not Implemented |
MI0294 # 05 Y:2016 | 05 | 2016 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $5,921 | $1,441 | Implemented |
SU0408 # 03 Y:2016 | 03 | 2016 | INSULATE FEEDWATER TANK | $48 | $31 | Implemented |
SU0408 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $1,194 | $2,183 | Implemented |
OK0935 # 03 Y:2016 | 03 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,052 | $1,913 | Not Implemented |
OK0935 # 09 Y:2016 | 09 | 2016 | COVER OPEN TANKS | $8,035 | $1,510 | Not Implemented |
NC0563 # 01 Y:2016 | 01 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,357 | $3,050 | Not Implemented |
NC0563 # 09 Y:2016 | 09 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $212 | $150 | Not Implemented |
MA0754 # 02 Y:2016 | 02 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $112,215 | $1,000 | Not Implemented |
MA0754 # 04 Y:2016 | 04 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $62,104 | $250,000 | Not Implemented |
OK0933 # 05 Y:2016 | 05 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $24,062 | $20,162 | Implemented |
OK0933 # 06 Y:2016 | 06 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,272 | $3,404 | Implemented |
OK0933 # 07 Y:2016 | 07 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $353 | $240 | Implemented |
WV0522 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $3,281 | $6,551 | Not Implemented |
LE0413 # 03 Y:2016 | 03 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,060 | $1,800 | Not Implemented |
LE0413 # 07 Y:2016 | 07 | 2016 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,462 | $25,000 | Implemented |
NC0562 # 03 Y:2016 | 03 | 2016 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $29,861 | $3,000 | Not Implemented |
UD0944 # 01 Y:2016 | 01 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,720 | $7,315 | Not Implemented |
UD0944 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $749 | $2,640 | Not Implemented |
UD0944 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $476 | $1,148 | Not Implemented |
WM0083 # 05 Y:2016 | 05 | 2016 | INSULATE BARE EQUIPMENT | $12,261 | $1,680 | Not Implemented |
LE0414 # 02 Y:2016 | 02 | 2016 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $34,860 | $36,000 | Implemented |
SD0525 # 02 Y:2016 | 02 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,754 | $16,450 | Not Implemented |
SD0525 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $1,494 | $527 | Not Implemented |