IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

503

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0482 # 11 Y:2014 11 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $6,903 $1,632 Implemented
BS0029 # 06 Y:2014 06 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,602 $33,371 Not Implemented
DL0124 # 02 Y:2014 02 2014 USE OPTIMUM TEMPERATURE $490 $0 Implemented
DL0124 # 03 Y:2014 03 2014 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $340 $0 Not Implemented
MZ0135 # 03 Y:2014 03 2014 INSULATE BARE EQUIPMENT $27,410 $1,821 Implemented
MZ0135 # 04 Y:2014 04 2014 RECOVER WASTE HEAT FROM EQUIPMENT $4,968 $1,420 Not Implemented
CO0683 # 03 Y:2014 03 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,270 $0 Not Implemented
CO0683 # 04 Y:2014 04 2014 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $2,440 $6,450 Not Implemented
MZ0136 # 07 Y:2014 07 2014 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $13,943 $63,000 Not Implemented
MZ0136 # 08 Y:2014 08 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $44,793 $7,900 Not Implemented
OR0626 # 05 Y:2014 05 2014 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $5,445 $6,461 Not Implemented
OR0626 # 06 Y:2014 06 2014 INSULATE BARE EQUIPMENT $3,138 $5,659 Not Implemented
SD0481 # 01 Y:2014 01 2014 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $134,111 $80,720 Implemented
SD0481 # 04 Y:2014 04 2014 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $22,759 $25,200 Not Implemented
SD0481 # 08 Y:2014 08 2014 REPAIR AND ELIMINATE STEAM LEAKS $2,220 $1,200 Implemented
SD0481 # 09 Y:2014 09 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $1,553 $2,325 Implemented
UD0899 # 04 Y:2014 04 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,795 $4,550 Not Implemented
UD0899 # 05 Y:2014 05 2014 USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS $2,075 $0 Implemented
UD0899 # 06 Y:2014 06 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,303 $0 Implemented
MZ0137 # 05 Y:2014 05 2014 RECOVER WASTE HEAT FROM EQUIPMENT $805 $1,475 Implemented
MA0725 # 02 Y:2014 02 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $263,264 $594,880 Not Implemented
MA0725 # 04 Y:2014 04 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $74,123 $120,280 Not Implemented
MA0725 # 05 Y:2014 05 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $28,833 $9,690 Implemented
MA0725 # 12 Y:2014 12 2014 INSULATE BARE EQUIPMENT $3,366 $30,760 Implemented
WV0481 # 02 Y:2014 02 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $14,611 $72,000 Not Implemented