Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

497

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0342 # 04 Y:1999 04 1999 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $285 $270 Not Implemented
UM0132 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $815 $990 Implemented
TN0651 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $3,020 $1,605 Implemented
UM0131 # 04 Y:1999 04 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $202 $510 n/a
UM0131 # 05 Y:1999 05 1999 REPAIR OR REPLACE STEAM TRAPS $2,646 $5,280 n/a
UM0131 # 06 Y:1999 06 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $14,658 $6,690 n/a
AM0341 # 04 Y:1999 04 1999 REPAIR AND ELIMINATE STEAM LEAKS $6,140 $780 Implemented
AM0341 # 08 Y:1999 08 1999 INSULATE BARE EQUIPMENT $540 $905 Implemented
AS0242 # 05 Y:1999 05 1999 USE OPTIMUM THICKNESS INSULATION $3,847 $383 Implemented
HO0192 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $2,083 $520 Implemented
MA0432 # 01 Y:1999 01 1999 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $9,010 $21,612 Not Implemented
DS0127 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $883 $692 Not Implemented
SD0211 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $21,102 $2,000 Not Implemented
SD0211 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $1,700 $370 Not Implemented
UF0217 # 03 Y:1999 03 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $4,574 $6,750 Not Implemented
MA0431 # 01 Y:1999 01 1999 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $9,010 $21,612 Not Implemented
OK0564 # 01 Y:1999 01 1999 INSULATE BARE EQUIPMENT $689 $701 Not Implemented
WI0338 # 07 Y:1999 07 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,906 $6,000 n/a
AM0340 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $3,080 $245 Implemented
AM0340 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $2,260 $785 Implemented
OK0563 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $14,128 $11,350 Implemented
AM0339 # 02 Y:1999 02 1999 REPAIR AND ELIMINATE STEAM LEAKS $2,575 $1,500 Implemented
AM0339 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $500 $212 Not Implemented
AM0339 # 08 Y:1999 08 1999 INSULATE BARE EQUIPMENT $240 $1,360 Implemented
ND0318 # 09 Y:1999 09 1999 COVER OPEN TANKS $347 $200 Not Implemented