Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,028
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0021 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,804 | $8,000 | Not Implemented |
LE0271 # 05 Y:2008 | 05 | 2008 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $14,909 | $30,000 | Not Implemented |
UA0021 # 07 Y:2008 | 07 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $6,002 | $986 | Implemented |
UA0021 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,292 | $2,550 | Not Implemented |
AM0550 # 02 Y:2008 | 02 | 2008 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $50,000 | $252,000 | Not Implemented |
OK0762 # 06 Y:2008 | 06 | 2008 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $238,891 | $232,766 | Implemented |
SF0356 # 07 Y:2008 | 07 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,534 | $10,979 | Not Implemented |
SF0356 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $2,504 | $3,760 | Not Implemented |
MA0638 # 08 Y:2008 | 08 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,670 | $3,000 | Implemented |
GT0849 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $35,083 | $40,800 | Not Implemented |
GT0849 # 04 Y:2008 | 04 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $292,310 | $18,200 | Implemented |
LL0292 # 09 Y:2008 | 09 | 2008 | INSULATE BARE EQUIPMENT | $80 | $242 | Implemented |
MA0638 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $43,903 | $225,000 | Not Implemented |
BD0342 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,573 | $751 | Not Implemented |
TT0018 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $314,600 | $100,000 | Not Implemented |
UD0780 # 09 Y:2008 | 09 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $4,058 | $700 | Not Implemented |
UD0780 # 01 Y:2008 | 01 | 2008 | INSULATE BARE EQUIPMENT | $31,350 | $8,290 | Not Implemented |
UD0780 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,375 | $30,000 | Not Implemented |
UD0780 # 03 Y:2008 | 03 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $14,100 | $18,000 | Not Implemented |
UD0780 # 04 Y:2008 | 04 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,693 | $7,000 | Implemented |
UD0780 # 12 Y:2008 | 12 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,587 | $950 | Not Implemented |
UD0780 # 02 Y:2008 | 02 | 2008 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $28,671 | $23,190 | Not Implemented |
BD0344 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $75,203 | $20,001 | Not Implemented |
LE0270 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $34,004 | $26,000 | Not Implemented |
LE0270 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,241 | $22,000 | Not Implemented |