Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0256 # 04 Y:2003 04 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $170 $1,730 Not Implemented
WV0256 # 10 Y:2003 10 2003 REPAIR AND ELIMINATE STEAM LEAKS $1,043 $1,000 Implemented
WV0255 # 03 Y:2003 03 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $965 $2,700 Not Implemented
WV0255 # 04 Y:2003 04 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $2,019 $200 Not Implemented
WV0255 # 07 Y:2003 07 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $27,449 $2,455 Not Implemented
WV0255 # 10 Y:2003 10 2003 REDUCE EXCESS STEAM BLEEDING $4,622 $80,000 Not Implemented
LE0151 # 03 Y:2003 03 2003 USE OPTIMUM THICKNESS INSULATION $51,426 $6,735 Implemented
CO0520 # 02 Y:2003 02 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $10,530 $39,900 Not Implemented
SF0252 # 03 Y:2003 03 2003 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $2,342 $4,612 Not Implemented
SU0153 # 02 Y:2003 02 2003 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $42,094 $93,819 Not Implemented
SU0153 # 03 Y:2003 03 2003 INCREASE AMOUNT OF CONDENSATE RETURNED $30,876 $11,602 Implemented
SU0153 # 08 Y:2003 08 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,098 $12,105 Not Implemented
UF0313 # 03 Y:2003 03 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $58,093 $31,024 Not Implemented
UF0313 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $7,223 $973 Implemented
UF0313 # 06 Y:2003 06 2003 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $19,080 $34,976 Not Implemented
UM0224 # 05 Y:2003 05 2003 REPAIR AND ELIMINATE STEAM LEAKS $26,100 $7,230 Implemented
UM0224 # 07 Y:2003 07 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $2,606 $934 Implemented
UM0224 # 08 Y:2003 08 2003 INSTALL STEAM TRAP $1,031 $4,360 Not Implemented
SU0151 # 03 Y:2003 03 2003 RECOVER WASTE HEAT FROM EQUIPMENT $3,604 $8,000 Not Implemented
SU0150 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,229 $6,100 Not Implemented
SF0251 # 01 Y:2003 01 2003 REPAIR OR REPLACE STEAM TRAPS $159,621 $0 Implemented
SF0251 # 02 Y:2003 02 2003 REPAIR AND ELIMINATE STEAM LEAKS $7,020 $516 Implemented
SF0251 # 06 Y:2003 06 2003 INSULATE BARE EQUIPMENT $8,716 $4,674 Not Implemented
SF0251 # 07 Y:2003 07 2003 RECOVER WASTE HEAT FROM EQUIPMENT $28,747 $21,620 Not Implemented
SF0251 # 09 Y:2003 09 2003 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,536 $1,360 Not Implemented