Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
199
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0388 # 05 Y:2021 | 05 | 2021 | REPAIR OR REPLACE STEAM TRAPS | $13,798 | $4,080 | Implemented |
WV0609 # 08 Y:2021 | 08 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,444 | $7,620 | Not Implemented |
WV0609 # 11 Y:2021 | 11 | 2021 | INSULATE BARE EQUIPMENT | $1,192 | $1,293 | Implemented |
MA0827 # 01 Y:2021 | 01 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $32,062 | $75,000 | Not Implemented |
MA0827 # 05 Y:2021 | 05 | 2021 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,962 | $10,800 | Not Implemented |
MA0827 # 07 Y:2021 | 07 | 2021 | INSULATE BARE EQUIPMENT | $801 | $1,550 | Not Implemented |
AM0823 # 06 Y:2021 | 06 | 2021 | INSULATE BARE EQUIPMENT | $23,744 | $1,095 | Not Implemented |
WM0163 # 01 Y:2021 | 01 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,131 | $40,000 | Not Implemented |
WM0163 # 03 Y:2021 | 03 | 2021 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $4,101 | $3,100 | Not Implemented |
UD1029 # 05 Y:2021 | 05 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,922 | $10,000 | Not Implemented |
UD1029 # 07 Y:2021 | 07 | 2021 | USE MINIMUM STEAM OPERATING PRESSURE | $1,533 | $0 | Not Implemented |
UD1029 # 09 Y:2021 | 09 | 2021 | TURN OFF STEAM TRACING DURING MILD WEATHER | $876 | $0 | Not Implemented |
UU0186 # 02 Y:2021 | 02 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,932 | $15,000 | Not Implemented |
IC0247 # 07 Y:2021 | 07 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,269 | $24,850 | Not Implemented |
BS0148 # 02 Y:2021 | 02 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,112 | $50,404 | Not Implemented |
BS0148 # 03 Y:2021 | 03 | 2021 | INSTALL / REPAIR INSULATION ON STEAM LINES | $445 | $649 | Not Implemented |
MA0826 # 03 Y:2021 | 03 | 2021 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,447 | $10,800 | Not Implemented |
NL0056 # 01 Y:2021 | 01 | 2021 | OPERATE DISTILLATION COLUMNS EFFICIENTLY | $222,300 | $82,500 | Implemented |
NL0056 # 03 Y:2021 | 03 | 2021 | REPAIR AND ELIMINATE STEAM LEAKS | $8,331 | $4,500 | Not Implemented |
UK2101 # 05 Y:2021 | 05 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,495 | $2,215 | n/a |
UK2101 # 10 Y:2021 | 10 | 2021 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,968 | $15,000 | n/a |
UU0185 # 01 Y:2021 | 01 | 2021 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $21,754 | $64,000 | Not Implemented |
LS2103 # 01 Y:2021 | 01 | 2021 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $35,907 | $250 | Implemented |
LS2103 # 05 Y:2021 | 05 | 2021 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $209,892 | $1,023,215 | Implemented |
UD1028 # 05 Y:2021 | 05 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,623 | $5,000 | Not Implemented |