Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19,997
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0044 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $38,154 | $31,020 | Not Implemented |
GT0566 # 04 Y:1995 | 04 | 1995 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $10,700 | $0 | Not Implemented |
ME0171 # 02 Y:1995 | 02 | 1995 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $4,951 | $3,480 | Not Implemented |
GT0566 # 02 Y:1995 | 02 | 1995 | USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC | $81,900 | $80,000 | Implemented |
IA0118 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $957 | $610 | Implemented |
UM0042 # 05 Y:1995 | 05 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $8,994 | $2,960 | n/a |
OR0246 # 01 Y:1995 | 01 | 1995 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $12,000 | $19,000 | Not Implemented |
NV0041 # 02 Y:1995 | 02 | 1995 | INSULATE BARE EQUIPMENT | $4,791 | $1,203 | Not Implemented |
NV0041 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $692 | $361 | Not Implemented |
NV0041 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $259 | $843 | Not Implemented |
UM0042 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $7,633 | $2,650 | n/a |
HO0116 # 04 Y:1995 | 04 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $96 | $53 | Not Implemented |
MS0041 # 05 Y:1995 | 05 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,305 | $700 | Not Implemented |
MS0041 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $404 | $130 | Not Implemented |
IA0121 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $672 | $440 | Not Implemented |
SF0072 # 04 Y:1995 | 04 | 1995 | COVER OPEN TANKS | $98 | $77 | Implemented |
UF0123 # 06 Y:1995 | 06 | 1995 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $12,460 | $11,600 | Not Implemented |
WI0252 # 06 Y:1995 | 06 | 1995 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $690 | $1,000 | Not Implemented |
WI0252 # 05 Y:1995 | 05 | 1995 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,698 | $5,500 | Not Implemented |
UF0132 # 06 Y:1995 | 06 | 1995 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,950 | $15,000 | Not Implemented |
HO0115 # 04 Y:1995 | 04 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $583 | $250 | Not Implemented |
UD0472 # 05 Y:1995 | 05 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,630 | $37,500 | Not Implemented |
UL0137 # 05 Y:1995 | 05 | 1995 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,738 | $625 | Implemented |
ND0234 # 02 Y:1995 | 02 | 1995 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $1,082 | $500 | Implemented |
IA0123 # 03 Y:1995 | 03 | 1995 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $764 | $2,562 | Implemented |