Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

605

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0342 # 06 Y:1995 06 1995 RECOVER WASTE HEAT FROM EQUIPMENT $820 $600 Implemented
UM0037 # 04 Y:1995 04 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $236 $300 Not Implemented
OR0244 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $14,400 $5,385 Not Implemented
SF0070 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $1,695 $1,918 Implemented
SF0070 # 08 Y:1995 08 1995 INSULATE FEEDWATER TANK $307 $702 Implemented
SF0070 # 09 Y:1995 09 1995 INCREASE AMOUNT OF CONDENSATE RETURNED $8,250 $1,620 Implemented
BD0040 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $3,916 $3,500 Implemented
NC0069 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $538 $864 Not Implemented
IA0125 # 01 Y:1995 01 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $38,625 $95,200 Not Implemented
CO0341 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $620 $650 Not Implemented
AS0159 # 08 Y:1995 08 1995 INSULATE BARE EQUIPMENT $8,844 $6,860 Not Implemented
AS0159 # 07 Y:1995 07 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $11,926 $31,350 Not Implemented
AS0159 # 06 Y:1995 06 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,366 $20,000 Not Implemented
OK0477 # 02 Y:1995 02 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $1,555 $951 Implemented
OK0477 # 03 Y:1995 03 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $1,030 $4,837 Not Implemented
OK0477 # 05 Y:1995 05 1995 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $497 $571 Implemented
NV0038 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $885 $189 Not Implemented
OD0038 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $697 $465 Not Implemented
WV0075 # 06 Y:1995 06 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,194 $1,085 Not Implemented
WV0075 # 12 Y:1995 12 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $323 $415 Implemented
MS0036 # 04 Y:1995 04 1995 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $3,275 $800 Not Implemented
MS0036 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,060 $1,510 Implemented
DS0030 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $97 $69 Not Implemented
BD0038 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,940 $1,500 Implemented
BD0037 # 01 Y:1995 01 1995 INSULATE BARE EQUIPMENT $602 $174 Not Implemented