Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,411

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0014 # 03 Y:1992 03 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $121 $104 Implemented
OK0372 # 01 Y:1992 01 1992 RECOVER WASTE HEAT FROM EQUIPMENT $588 $807 Not Implemented
AS0052 # 09 Y:1992 09 1992 RECOVER WASTE HEAT FROM EQUIPMENT $4,913 $4,491 Implemented
CO0240 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $330 $125 Implemented
CO0240 # 03 Y:1992 03 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $785 $250 Implemented
CO0239 # 05 Y:1992 05 1992 RECOVER WASTE HEAT FROM EQUIPMENT $2,730 $670 Implemented
CO0241 # 06 Y:1992 06 1992 INSULATE BARE EQUIPMENT $340 $450 Implemented
OK0370 # 04 Y:1992 04 1992 RECOVER WASTE HEAT FROM EQUIPMENT $2,461 $405 Implemented
RU0137 # 01 Y:1992 01 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $680 $426 Implemented
RU0143 # 03 Y:1992 03 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $1,855 $930 Implemented
SD0016 # 04 Y:1992 04 1992 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $459 $109 Not Implemented
SD0017 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $77 $214 Not Implemented
KU0365 # 01 Y:1992 01 1992 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $13,442 $0 Not Implemented
KU0365 # 02 Y:1992 02 1992 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $6,266 $31,766 Implemented
KU0365 # 06 Y:1992 06 1992 RECOVER WASTE HEAT FROM EQUIPMENT $400 $900 Not Implemented
KU0366 # 01 Y:1992 01 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,148 $6,400 Not Implemented
KU0366 # 07 Y:1992 07 1992 RECOVER WASTE HEAT FROM EQUIPMENT $407 $350 Not Implemented
KU0366 # 12 Y:1992 12 1992 RECOVER WASTE HEAT FROM EQUIPMENT $133 $200 Not Implemented
UF0025 # 08 Y:1992 08 1992 HEAT WATER WITH EXHAUST HEAT $569 $1,200 Not Implemented
WI0140 # 07 Y:1992 07 1992 RECOVER WASTE HEAT FROM EQUIPMENT $109 $500 Not Implemented
WI0142 # 05 Y:1992 05 1992 COVER OPEN TANKS $967 $500 Not Implemented
MA0237 # 01 Y:1992 01 1992 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $19,462 $200 Implemented
MA0237 # 02 Y:1992 02 1992 INCREASE AMOUNT OF CONDENSATE RETURNED $6,172 $1,000 Implemented
MA0237 # 06 Y:1992 06 1992 INSULATE BARE EQUIPMENT $2,398 $200 Implemented
MA0238 # 01 Y:1992 01 1992 USE OPTIMUM TEMPERATURE $22,238 $2,775 Not Implemented