Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

497

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0141 # 06 Y:1999 06 1999 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,014 $1,250 Not Implemented
KU0524 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $750 $680 Implemented
DS0147 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $635 $1,156 Not Implemented
OR0354 # 01 Y:1999 01 1999 CLOSE OFF UNNEEDED STEAM LINES $5,250 $950 Implemented
OR0354 # 02 Y:1999 02 1999 USE MINIMUM STEAM OPERATING PRESSURE $560 $0 Not Implemented
HO0211 # 09 Y:1999 09 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,690 $1,400 Not Implemented
UM0148 # 02 Y:1999 02 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,069 $500 Not Implemented
ND0326 # 01 Y:1999 01 1999 PREHEAT COMBUSTION AIR WITH WASTE HEAT $214,338 $180,000 Not Implemented
OR0354 # 05 Y:1999 05 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $950 $0 Not Implemented
UF0231 # 03 Y:1999 03 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $1,596 $450 Implemented
UF0231 # 04 Y:1999 04 1999 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $12,394 $42,085 Not Implemented
UF0231 # 06 Y:1999 06 1999 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $62,712 $2,200 Not Implemented
OR0352 # 01 Y:1999 01 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $60,160 $81,250 Not Implemented
OR0352 # 02 Y:1999 02 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,270 $3,200 Not Implemented
WV0178 # 09 Y:1999 09 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,104 $1,315 Not Implemented
ME0272 # 02 Y:1999 02 1999 RECOVER WASTE HEAT FROM EQUIPMENT $11,434 $2,159 Implemented
WV0178 # 07 Y:1999 07 1999 RECOVER WASTE HEAT FROM EQUIPMENT $5,726 $870 Not Implemented
ME0272 # 11 Y:1999 11 1999 INSULATE BARE EQUIPMENT $1,899 $1,260 Implemented
WV0178 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $7,766 $2,000 Implemented
OR0352 # 05 Y:1999 05 1999 COVER OPEN TANKS $1,940 $870 Not Implemented
OR0352 # 06 Y:1999 06 1999 COVER OPEN TANKS $2,130 $5,385 Not Implemented
OR0352 # 04 Y:1999 04 1999 USE OPTIMUM THICKNESS INSULATION $3,970 $950 Not Implemented
WV0178 # 01 Y:1999 01 1999 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $23,912 $0 Not Implemented
ME0272 # 01 Y:1999 01 1999 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $19,520 $4,860 Not Implemented
OR0351 # 03 Y:1999 03 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,590 $0 Implemented