Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,052
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0428 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,236 | $60,550 | Implemented |
WV0428 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $11,317 | $815 | Implemented |
WV0428 # 06 Y:2011 | 06 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,763 | $1,000 | Implemented |
WV0428 # 09 Y:2011 | 09 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,253 | $2,000 | Implemented |
WV0428 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,120 | $700 | Implemented |
WV0428 # 14 Y:2011 | 14 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,082 | $600 | Implemented |
WV0428 # 15 Y:2011 | 15 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,154 | $25 | Implemented |
UD0827 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $995 | $500 | Implemented |
UD0827 # 07 Y:2010 | 07 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $597 | $50 | Implemented |
TT0053 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,700 | $10,500 | Implemented |
TT0053 # 03 Y:2010 | 03 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,000 | $10 | Implemented |
TT0053 # 04 Y:2010 | 04 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $2,700 | $1,000 | Implemented |
UD0797 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,489 | $48,750 | Implemented |
UD0797 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,034 | $1,000 | Implemented |
UD0797 # 09 Y:2009 | 09 | 2009 | DISCONNECT BALLASTS | $858 | $0 | Implemented |
UD0788 # 01 Y:2008 | 01 | 2008 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $49,954 | $12,500 | Implemented |
UD0788 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $26,537 | $21,250 | Implemented |
UD0788 # 04 Y:2008 | 04 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $20,385 | $440 | Implemented |
UD0788 # 06 Y:2008 | 06 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $13,860 | $0 | Implemented |
UD0788 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $2,123 | $3,500 | Implemented |
UD0788 # 09 Y:2008 | 09 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $1,037 | $200 | Implemented |
UD0788 # 10 Y:2008 | 10 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $590 | $0 | Implemented |
UD0788 # 11 Y:2008 | 11 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $372 | $0 | Implemented |
TT0010 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,100 | $2,500 | Implemented |
TT0010 # 04 Y:2008 | 04 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,700 | $11,500 | Implemented |