Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,405
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0144 # 03 Y:2008 | 03 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $461 | $0 | Implemented |
IC0144 # 04 Y:2008 | 04 | 2008 | INSTALL OCCUPANCY SENSORS | $533 | $781 | Implemented |
IC0144 # 05 Y:2008 | 05 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $68 | $0 | Implemented |
IC0144 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,031 | $4,364 | Implemented |
IC0144 # 07 Y:2008 | 07 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,002 | $2,000 | Implemented |
IC0144 # 09 Y:2008 | 09 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $222 | $0 | Implemented |
IC0144 # 12 Y:2008 | 12 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $48 | $0 | Implemented |
IC0144 # 13 Y:2008 | 13 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $633 | $920 | Implemented |
IC0143 # 02 Y:2008 | 02 | 2008 | DISCONNECT BALLASTS | $26 | $26 | Implemented |
IC0143 # 03 Y:2008 | 03 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $338 | $0 | Implemented |
IC0143 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $944 | $162 | Implemented |
IC0143 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $142 | Implemented |
IC0143 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,385 | $1,541 | Implemented |
IC0143 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,544 | $1,035 | Implemented |
IC0143 # 09 Y:2008 | 09 | 2008 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,040 | $37 | Implemented |
IC0143 # 11 Y:2008 | 11 | 2008 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,202 | $32,361 | Implemented |
IC0143 # 12 Y:2008 | 12 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $541 | $0 | Implemented |
IC0136 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,802 | $9,080 | Implemented |
IC0136 # 02 Y:2007 | 02 | 2007 | INSTALL OCCUPANCY SENSORS | $2,224 | $5,038 | Implemented |
IC0136 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,389 | $3,105 | Implemented |
IC0132 # 01 Y:2007 | 01 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $906 | $0 | Implemented |
IC0132 # 03 Y:2007 | 03 | 2007 | OPTIMIZE PLANT POWER FACTOR | $8,296 | $19,530 | Implemented |
IC0132 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $654 | $1,962 | Implemented |
IC0132 # 07 Y:2007 | 07 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $396 | $0 | Implemented |
IC0129 # 01 Y:2007 | 01 | 2007 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,537 | $81,554 | Implemented |