Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
123
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0492 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,090 | $450 | Implemented |
UD0403 # 02 Y:1993 | 02 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,715 | $25,000 | Implemented |
AR0002 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $387 | $1,000 | Implemented |
SF0001 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,366 | $800 | Implemented |
SF0001 # 04 Y:1993 | 04 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $344 | $625 | Implemented |
UD0401 # 02 Y:1993 | 02 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,994 | $300 | Implemented |
ME0105 # 04 Y:1993 | 04 | 1993 | MOVE BOILER TO MORE EFFICIENT LOCATION | $256 | $200 | Implemented |
UD0400 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,689 | $29,000 | Implemented |
UD0400 # 06 Y:1993 | 06 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,699 | $250 | Implemented |
NC0001 # 02 Y:1993 | 02 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,100 | $500 | Implemented |
WI0178 # 09 Y:1993 | 09 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $143 | $500 | Implemented |
MA0270 # 02 Y:1993 | 02 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,894 | $0 | Implemented |
MA0270 # 04 Y:1993 | 04 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,159 | $400 | Implemented |
ME0104 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,808 | $0 | Implemented |
MO0083 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,699 | $2,195 | Implemented |
ME0103 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,120 | $700 | Implemented |
SD0052 # 03 Y:1993 | 03 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $312 | $658 | Implemented |
SD0052 # 05 Y:1993 | 05 | 1993 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $9,280 | $2,450 | Implemented |
AS0082 # 02 Y:1993 | 02 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $270 | $400 | Implemented |
KU0396 # 02 Y:1993 | 02 | 1993 | USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING | $6,812 | $6,925 | Implemented |
OR0172 # 02 Y:1993 | 02 | 1993 | KEEP BOILER TUBES CLEAN | $1,216 | $1,000 | Implemented |
OK0399 # 08 Y:1993 | 08 | 1993 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $743 | $880 | Implemented |
OR0170 # 04 Y:1993 | 04 | 1993 | KEEP BOILER TUBES CLEAN | $1,644 | $1,000 | Implemented |
SD0050 # 02 Y:1993 | 02 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $178 | $214 | Implemented |
SD0050 # 04 Y:1993 | 04 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,354 | $25,076 | Implemented |