Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,018
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0531 # 02 Y:2016 | 02 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,039 | $63,000 | Not Implemented |
WV0531 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $12,371 | $25,305 | Implemented |
MI0302 # 01 Y:2016 | 01 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $12,170 | $29,740 | Implemented |
MI0302 # 06 Y:2016 | 06 | 2016 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $2,171 | $260 | Not Implemented |
UM0471 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $696 | $2,500 | n/a |
UM0471 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,664 | $3,435 | n/a |
WM0091 # 01 Y:2016 | 01 | 2016 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $12,568 | $2,860 | Not Implemented |
BS0081 # 03 Y:2016 | 03 | 2016 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $72 | $311 | Not Implemented |
SF0488 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $6,138 | $882 | Implemented |
SF0488 # 08 Y:2016 | 08 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,810 | $61,903 | Not Implemented |
SF0489 # 01 Y:2016 | 01 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $29,223 | $350 | Implemented |
SF0489 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $3,011 | $3,675 | Not Implemented |
MI0301 # 06 Y:2016 | 06 | 2016 | USE OPTIMUM THICKNESS INSULATION | $2,946 | $2,710 | Not Implemented |
MI0301 # 07 Y:2016 | 07 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,197 | $2,146 | Not Implemented |
OK0948 # 06 Y:2016 | 06 | 2016 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $27,228 | $83,600 | Implemented |
OK0948 # 08 Y:2016 | 08 | 2016 | USE OPTIMUM THICKNESS INSULATION | $382 | $1,310 | Implemented |
OK0948 # 09 Y:2016 | 09 | 2016 | USE OPTIMUM THICKNESS INSULATION | $58 | $203 | Implemented |
BS0080 # 07 Y:2016 | 07 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,626 | $8,468 | Not Implemented |
BS0083 # 03 Y:2016 | 03 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,462 | $3,018 | Not Implemented |
UK1605 # 12 Y:2016 | 12 | 2016 | CLEAN CONDENSER TUBES | $5,812 | $63 | Not Implemented |
UK1605 # 14 Y:2016 | 14 | 2016 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $58,000 | $120,000 | Not Implemented |
UK1605 # 16 Y:2016 | 16 | 2016 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,000 | $12,000 | Not Implemented |
MI0300 # 12 Y:2016 | 12 | 2016 | USE OPTIMUM THICKNESS INSULATION | $6,276 | $1,644 | Not Implemented |
DL0166 # 01 Y:2016 | 01 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,095 | $1,036 | Implemented |
DL0166 # 02 Y:2016 | 02 | 2016 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $4,815 | $27,020 | Not Implemented |