Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,022

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0364 # 09 Y:2012 09 2012 INSULATE BARE EQUIPMENT $178 $165 Not Implemented
MS0386 # 03 Y:2012 03 2012 RECOVER WASTE HEAT FROM EQUIPMENT $6,854 $7,104 Not Implemented
GT0888 # 04 Y:2012 04 2012 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $2,915 $1,680 Not Implemented
GT0888 # 05 Y:2012 05 2012 RECOVER WASTE HEAT FROM EQUIPMENT $17,200 $15,000 Not Implemented
NC0441 # 08 Y:2012 08 2012 INCREASE AMOUNT OF CONDENSATE RETURNED $462 $600 Implemented
NC0441 # 10 Y:2012 10 2012 REPAIR OR REPLACE STEAM TRAPS $1,119 $1,000 Implemented
MZ0073 # 04 Y:2011 04 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $9,393 $4,500 Not Implemented
DL0078 # 08 Y:2011 08 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $23,761 $22,500 Not Implemented
UA0071 # 07 Y:2011 07 2011 RECOVER WASTE HEAT FROM EQUIPMENT $22,837 $1,752 Not Implemented
MS0385 # 01 Y:2011 01 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,422 $5,076 Not Implemented
WV0439 # 10 Y:2011 10 2011 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,477 $144 Implemented
WV0439 # 11 Y:2011 11 2011 INSULATE BARE EQUIPMENT $4,234 $972 Implemented
WV0439 # 13 Y:2011 13 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,536 $9,580 Not Implemented
UA0069 # 05 Y:2011 05 2011 RECOVER WASTE HEAT FROM EQUIPMENT $678 $2,578 Not Implemented
UA0069 # 06 Y:2011 06 2011 USE OPTIMUM THICKNESS INSULATION $25,829 $16,900 Not Implemented
UA0069 # 07 Y:2011 07 2011 USE OPTIMUM THICKNESS INSULATION $5,314 $1,750 Not Implemented
UA0069 # 08 Y:2011 08 2011 USE OPTIMUM THICKNESS INSULATION $6,558 $7,600 Not Implemented
WV0438 # 02 Y:2011 02 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,986 $25,242 Not Implemented
WV0438 # 03 Y:2011 03 2011 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $23,750 $68,377 Not Implemented
WV0438 # 06 Y:2011 06 2011 INSULATE BARE EQUIPMENT $10,092 $2,424 Not Implemented
MZ0077 # 07 Y:2011 07 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,741 $28,000 Not Implemented
UD0844 # 12 Y:2011 12 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,508 $16,000 Not Implemented
UD0844 # 13 Y:2011 13 2011 USE OPTIMUM TEMPERATURE $3,225 $0 Not Implemented
OK0818 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $1,355 $4,015 Not Implemented
BD0401 # 04 Y:2011 04 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,685 $3,000 Not Implemented