Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,025
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0050 # 06 Y:2010 | 06 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $70,430 | $4,075 | Not Implemented |
WV0401 # 01 Y:2010 | 01 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $61,713 | $37,440 | Not Implemented |
WV0401 # 03 Y:2010 | 03 | 2010 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $38,419 | $128,000 | Implemented |
MI0188 # 08 Y:2010 | 08 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,050 | $2,904 | Implemented |
MI0188 # 09 Y:2010 | 09 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,341 | $1,800 | Implemented |
UA0049 # 02 Y:2010 | 02 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,150 | $384 | Implemented |
UA0049 # 08 Y:2010 | 08 | 2010 | USE OPTIMUM THICKNESS INSULATION | $13,000 | $13,430 | Not Implemented |
UA0049 # 09 Y:2010 | 09 | 2010 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $2,800 | $2,000 | Implemented |
MS0351 # 02 Y:2010 | 02 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $80,833 | $872 | Implemented |
UA0047 # 06 Y:2010 | 06 | 2010 | OPTIMIZE OPERATION OF MULTI-STAGE VACUUM STEAM JETS | $155,078 | $222,874 | Not Implemented |
UA0047 # 07 Y:2010 | 07 | 2010 | INSULATE BARE EQUIPMENT | $1,140 | $713 | Not Implemented |
UD0814 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $18,417 | $9,030 | Not Implemented |
UD0814 # 09 Y:2010 | 09 | 2010 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $8,568 | $3,000 | Implemented |
UD0814 # 10 Y:2010 | 10 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,017 | $400 | Implemented |
UD0814 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $1,111 | $807 | Not Implemented |
UA0046 # 04 Y:2010 | 04 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,752 | $1,750 | Not Implemented |
LE0297 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,239 | $1,000 | Not Implemented |
SF0382 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $9,146 | $2,700 | Implemented |
SF0382 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $53,897 | $49,178 | Implemented |
SF0382 # 09 Y:2010 | 09 | 2010 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $165,218 | $158,868 | Not Implemented |
SF0383 # 05 Y:2010 | 05 | 2010 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,340 | $20,638 | Not Implemented |
SF0383 # 06 Y:2010 | 06 | 2010 | INSULATE BARE EQUIPMENT | $222 | $1,278 | Not Implemented |
UA0045 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $27,056 | $4,100 | Not Implemented |
UD0813 # 07 Y:2010 | 07 | 2010 | COVER OPEN TANKS | $1,343 | $716 | Not Implemented |
UD0813 # 08 Y:2010 | 08 | 2010 | COVER OPEN TANKS | $1,089 | $936 | Not Implemented |