Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,025

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0443 # 07 Y:2009 07 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,188 $500 Not Implemented
IA0443 # 09 Y:2009 09 2009 USE OPTIMUM THICKNESS INSULATION $14,294 $11,978 Not Implemented
WV0394 # 02 Y:2009 02 2009 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $22,727 $50,200 Implemented
WV0394 # 03 Y:2009 03 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $19,052 $63,760 Not Implemented
WV0394 # 05 Y:2009 05 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,870 $8,495 Not Implemented
WV0394 # 07 Y:2009 07 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,911 $4,500 Not Implemented
WV0394 # 11 Y:2009 11 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $1,448 $619 Implemented
WV0394 # 12 Y:2009 12 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,118 $1,017 Not Implemented
TT0036 # 04 Y:2009 04 2009 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $21,675 $30,000 Not Implemented
TT0038 # 02 Y:2009 02 2009 REPAIR AND ELIMINATE STEAM LEAKS $21,918 $10,000 Implemented
UD0803 # 02 Y:2009 02 2009 REPAIR OR REPLACE STEAM TRAPS $21,371 $3,376 Implemented
UD0803 # 05 Y:2009 05 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,360 $19,600 Not Implemented
UD0803 # 14 Y:2009 14 2009 ISOLATE HOT OR COLD EQUIPMENT $1,120 $0 Not Implemented
LE0291 # 01 Y:2009 01 2009 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $32,078 $50,000 Not Implemented
NC0393 # 01 Y:2009 01 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $32,824 $74,000 Not Implemented
DL0040 # 02 Y:2009 02 2009 RECOVER WASTE HEAT FROM EQUIPMENT $2,331 $2,350 Implemented
UM0356 # 01 Y:2009 01 2009 RECOVER WASTE HEAT FROM EQUIPMENT $140,582 $6,000 Not Implemented
UM0356 # 02 Y:2009 02 2009 RECOVER WASTE HEAT FROM EQUIPMENT $36,798 $13,000 Not Implemented
UM0356 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $12,510 $3,000 Not Implemented
WV0393 # 04 Y:2009 04 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,419 $4,400 Not Implemented
WV0393 # 06 Y:2009 06 2009 RECOVER WASTE HEAT FROM EQUIPMENT $2,691 $2,450 Not Implemented
WV0393 # 07 Y:2009 07 2009 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $2,298 $3,800 Implemented
MA0652 # 02 Y:2009 02 2009 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $10,132 $23,474 Implemented
LL0315 # 07 Y:2009 07 2009 INSULATE BARE EQUIPMENT $44 $177 Not Implemented
UF0426 # 15 Y:2009 15 2009 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $111,037 $4,000 Not Implemented