Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,028
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0547 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $65,750 | $20,000 | Not Implemented |
AM0547 # 08 Y:2008 | 08 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $170 | $390 | Not Implemented |
UF0411 # 06 Y:2008 | 06 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $888 | $364 | Not Implemented |
UF0411 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,348 | $20,000 | Not Implemented |
UF0411 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,520 | $1,000 | Not Implemented |
UF0411 # 12 Y:2008 | 12 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,419 | $3,400 | Not Implemented |
UM0337 # 06 Y:2008 | 06 | 2008 | INSULATE BARE EQUIPMENT | $791 | $478 | Implemented |
UA0018 # 04 Y:2008 | 04 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $21,032 | $15,500 | Not Implemented |
UA0018 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,848 | $6,050 | Implemented |
UA0018 # 06 Y:2008 | 06 | 2008 | INSULATE BARE EQUIPMENT | $5,592 | $840 | Implemented |
UA0018 # 11 Y:2008 | 11 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,404 | $30,900 | Not Implemented |
UD0778 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $77,393 | $80,770 | Not Implemented |
UD0778 # 04 Y:2008 | 04 | 2008 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $5,905 | $18,000 | Not Implemented |
CO0611 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,810 | $33,480 | Not Implemented |
DL0011 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $1,472 | $268 | Not Implemented |
MS0327 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $41,488 | $312 | Implemented |
MI0165 # 01 Y:2008 | 01 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $94,777 | $315,000 | Not Implemented |
MI0165 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $4,023 | $1,957 | Implemented |
UW0011 # 02 Y:2008 | 02 | 2008 | INSULATE BARE EQUIPMENT | $7,908 | $15,906 | Not Implemented |
MA0637 # 01 Y:2008 | 01 | 2008 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $254,315 | $250,000 | Not Implemented |
MA0637 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $169,795 | $80,000 | Not Implemented |
IA0423 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,458 | $617 | Implemented |
IA0422 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,842 | $2,300 | Not Implemented |
IA0422 # 06 Y:2008 | 06 | 2008 | INSULATE BARE EQUIPMENT | $6,865 | $6,165 | Implemented |
OR0528 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,800 | $16,950 | Not Implemented |