Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,458
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0267 # 05 Y:2008 | 05 | 2008 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $21,795 | $30,000 | Not Implemented |
BD0336 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $106 | $151 | Not Implemented |
TT0015 # 02 Y:2007 | 02 | 2007 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $17,800 | $35,600 | Not Implemented |
TT0015 # 03 Y:2007 | 03 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $2,000 | $1,600 | Implemented |
UD0773 # 03 Y:2008 | 03 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $22,200 | $15,000 | Implemented |
UD0773 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $16,500 | $30,000 | Not Implemented |
MA0628 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $305 | $290 | Implemented |
MI0160 # 04 Y:2008 | 04 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $11,340 | $15,475 | Not Implemented |
AM0536 # 01 Y:2008 | 01 | 2008 | INSULATE BARE EQUIPMENT | $26,800 | $4,160 | Implemented |
AM0537 # 07 Y:2008 | 07 | 2008 | INSULATE BARE EQUIPMENT | $15,000 | $12,000 | Implemented |
AM0537 # 11 Y:2008 | 11 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $1,890 | $500 | Implemented |
DL0010 # 03 Y:2007 | 03 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $4,305 | $225 | Implemented |
MI0158 # 06 Y:2007 | 06 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $13,330 | $1,700 | Implemented |
SF0350 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $1,126 | $2,145 | Not Implemented |
UA0013 # 05 Y:2007 | 05 | 2007 | USE OPTIMUM THICKNESS INSULATION | $3,027 | $279 | Not Implemented |
MA0626 # 03 Y:2007 | 03 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $5,346 | $0 | Not Implemented |
MA0626 # 04 Y:2007 | 04 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $3,465 | $2,500 | Not Implemented |
MA0626 # 06 Y:2007 | 06 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $395 | $200 | Not Implemented |
OK0754 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,351 | $4,638 | Implemented |
OK0754 # 09 Y:2007 | 09 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $8,086 | $0 | Implemented |
OK0753 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $4,874 | $9,950 | Not Implemented |
OK0753 # 07 Y:2007 | 07 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,437 | $13,500 | Not Implemented |
OR0526 # 04 Y:2007 | 04 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,200 | $30,000 | Implemented |
UD0771 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,342 | $600 | Not Implemented |
UD0771 # 08 Y:2007 | 08 | 2007 | INSULATE BARE EQUIPMENT | $1,182 | $1,450 | Not Implemented |