Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,028
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0755 # 10 Y:2007 | 10 | 2007 | USE OPTIMUM THICKNESS INSULATION | $4,545 | $16,005 | Not Implemented |
MA0612 # 03 Y:2007 | 03 | 2007 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $23,433 | $12,750 | Not Implemented |
UD0755 # 01 Y:2007 | 01 | 2007 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $73,500 | $147,000 | Implemented |
LL0269 # 04 Y:2007 | 04 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $22,967 | $178,238 | Not Implemented |
LL0269 # 02 Y:2007 | 02 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $60,227 | $12,430 | Implemented |
UD0754 # 06 Y:2007 | 06 | 2007 | INSULATE BARE EQUIPMENT | $15,104 | $5,930 | Not Implemented |
UD0754 # 08 Y:2007 | 08 | 2007 | COVER OPEN TANKS | $2,295 | $355 | Not Implemented |
UD0754 # 07 Y:2007 | 07 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,977 | $11,246 | Not Implemented |
UD0754 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $135,639 | $80,000 | Implemented |
MA0611 # 05 Y:2007 | 05 | 2007 | USE OPTIMUM TEMPERATURE | $6,194 | $12,675 | Not Implemented |
MA0611 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $98,826 | $74,772 | Implemented |
OK0741 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,334 | $7,480 | Not Implemented |
MS0311 # 07 Y:2007 | 07 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $385 | $476 | Not Implemented |
OR0514 # 03 Y:2007 | 03 | 2007 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,900 | $500 | Not Implemented |
MA0611 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $3,330 | $3,300 | Implemented |
UF0396 # 07 Y:2007 | 07 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $731 | $810 | Implemented |
OR0514 # 04 Y:2007 | 04 | 2007 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $4,400 | $1,000 | Not Implemented |
SF0339 # 01 Y:2007 | 01 | 2007 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $105,374 | $0 | Implemented |
IA0403 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $984 | $750 | Implemented |
LE0251 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $18,340 | $24,000 | Implemented |
BD0322 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $30,494 | $1,500 | Not Implemented |
BD0322 # 10 Y:2007 | 10 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $56,660 | $60,000 | Not Implemented |
WV0354 # 09 Y:2007 | 09 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,465 | $1,032 | Not Implemented |
WV0354 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,128 | $900 | Implemented |
LL0267 # 01 Y:2007 | 01 | 2007 | INSULATE BARE EQUIPMENT | $23,653 | $3,315 | Implemented |