IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,459

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0717 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $1,466 $1,039 Implemented
CO0576 # 04 Y:2005 04 2005 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $200 $170 Implemented
CO0576 # 07 Y:2005 07 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,740 $980 Not Implemented
MA0588 # 01 Y:2005 01 2005 INSULATE BARE EQUIPMENT $3,404 $2,197 Implemented
MA0588 # 02 Y:2005 02 2005 USE MINIMUM STEAM OPERATING PRESSURE $2,294 $500 Implemented
MA0583 # 08 Y:2005 08 2005 RECOVER WASTE HEAT FROM EQUIPMENT $79 $318 Implemented
OK0718 # 05 Y:2005 05 2005 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $2,243 $5,175 Not Implemented
OK0718 # 06 Y:2005 06 2005 INSULATE BARE EQUIPMENT $1,343 $1,693 Implemented
OK0718 # 07 Y:2005 07 2005 USE OPTIMUM THICKNESS INSULATION $2,162 $1,710 Implemented
NC0324 # 05 Y:2005 05 2005 RECOVER WASTE HEAT FROM EQUIPMENT $2,365 $3,749 Not Implemented
SU0221 # 08 Y:2005 08 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,125 $5,000 Not Implemented
UD0730 # 03 Y:2005 03 2005 MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS $13,381 $25,000 Not Implemented
UD0730 # 04 Y:2005 04 2005 COVER OPEN TANKS $12,069 $2,170 Not Implemented
UD0730 # 05 Y:2005 05 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,473 $12,880 Implemented
UD0730 # 06 Y:2005 06 2005 INSULATE BARE EQUIPMENT $5,769 $4,350 Not Implemented
UD0730 # 10 Y:2005 10 2005 USE MINIMUM SAFE OVEN VENTILATION $3,222 $150 Not Implemented
UD0730 # 13 Y:2005 13 2005 COVER OPEN TANKS $315 $0 Not Implemented
IC0109 # 02 Y:2005 02 2005 INSTALL WASTE HEAT BOILER TO PRODUCE STEAM $437,212 $3,259,200 Not Implemented
IC0109 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $17,632 $22,464 Not Implemented
IC0109 # 05 Y:2005 05 2005 REPAIR AND ELIMINATE STEAM LEAKS $1,239 $400 Implemented
IC0109 # 06 Y:2005 06 2005 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $37,809 $131,160 Not Implemented
OR0489 # 07 Y:2005 07 2005 INSULATE BARE EQUIPMENT $1,800 $2,100 Implemented
NC0323 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $2,020 $3,726 Not Implemented
AM0496 # 01 Y:2005 01 2005 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $35,000 $102,400 Not Implemented
BD0293 # 03 Y:2005 03 2005 RECOVER WASTE HEAT FROM EQUIPMENT $824 $2,100 Implemented