Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
370
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1908 # 11 Y:2019 | 11 | 2019 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $13,831 | $5,000 | Not Implemented |
UK1908 # 17 Y:2019 | 17 | 2019 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $1,430 | $0 | Implemented |
UK1908 # 18 Y:2019 | 18 | 2019 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $21,879 | $28,230 | Not Implemented |
BS0126 # 04 Y:2019 | 04 | 2019 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,406 | $13,000 | Not Implemented |
NC0638 # 01 Y:2019 | 01 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,797 | $85,000 | Not Implemented |
NC0638 # 02 Y:2019 | 02 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,807 | $3,600 | Not Implemented |
NC0638 # 03 Y:2019 | 03 | 2019 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $6,164 | $6,700 | Not Implemented |
TT0226 # 03 Y:2019 | 03 | 2019 | INSULATE BARE EQUIPMENT | $31,634 | $2,200 | Not Implemented |
AS0477 # 02 Y:2019 | 02 | 2019 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $64,747 | $120,000 | Implemented |
MZ0278 # 01 Y:2019 | 01 | 2019 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $902,475 | $6,762,500 | Implemented |
MZ0278 # 06 Y:2019 | 06 | 2019 | INSULATE BARE EQUIPMENT | $45,917 | $2,907 | Implemented |
MZ0278 # 08 Y:2019 | 08 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $35,571 | $11,900 | Not Implemented |
GT0929 # 05 Y:2019 | 05 | 2019 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,348 | $8,500 | Not Implemented |
BS0125 # 05 Y:2019 | 05 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $7,006 | $5,147 | Not Implemented |
BS0125 # 11 Y:2019 | 11 | 2019 | AVOID FROST FORMATION ON EVAPORATORS | $2,258 | $618 | Not Implemented |
LS1909 # 03 Y:2019 | 03 | 2019 | REPAIR AND ELIMINATE STEAM LEAKS | $2,121 | $585 | Implemented |
UD1000 # 03 Y:2019 | 03 | 2019 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,599 | $0 | Implemented |
UD1000 # 04 Y:2019 | 04 | 2019 | USE OPTIMUM THICKNESS INSULATION | $2,318 | $290 | Not Implemented |
UD1000 # 07 Y:2019 | 07 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $24,374 | $48,748 | Not Implemented |
IP0123 # 07 Y:2019 | 07 | 2019 | INSULATE BARE EQUIPMENT | $96 | $200 | Not Implemented |
IP0123 # 10 Y:2019 | 10 | 2019 | INSULATE BARE EQUIPMENT | $153 | $692 | Not Implemented |
UA0213 # 05 Y:2019 | 05 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,067 | $30,000 | Not Implemented |
UA0213 # 06 Y:2019 | 06 | 2019 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,399 | $4,370 | Not Implemented |
UA0214 # 05 Y:2019 | 05 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,824 | $6,704 | Implemented |
UU0153 # 04 Y:2019 | 04 | 2019 | INSULATE BARE EQUIPMENT | $5,443 | $502 | Not Implemented |