Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

516

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0195 # 10 Y:1993 10 1993 INSULATE BARE EQUIPMENT $187 $660 Not Implemented
GT0516 # 03 Y:1993 03 1993 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $72,000 $40,000 Not Implemented
SD0070 # 04 Y:1993 04 1993 UTILIZE A LESS EXPENSIVE COOLING METHOD $6,505 $15,000 Implemented
GT0515 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $45,330 $32,700 Not Implemented
UD0420 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $3,897 $3,000 Implemented
OK0422 # 02 Y:1993 02 1993 INCREASE AMOUNT OF CONDENSATE RETURNED $126,322 $90,000 Implemented
GT0514 # 04 Y:1993 04 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,600 $10,000 Not Implemented
OK0422 # 01 Y:1993 01 1993 REPAIR OR REPLACE STEAM TRAPS $170,442 $0 Implemented
OK0422 # 06 Y:1993 06 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $671 $866 Implemented
OK0422 # 03 Y:1993 03 1993 REPAIR OR REPLACE STEAM TRAPS $106,473 $4,025 Implemented
OK0422 # 05 Y:1993 05 1993 RECOVER WASTE HEAT FROM EQUIPMENT $3,201 $7,220 Not Implemented
SF0015 # 02 Y:1993 02 1993 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,821 $20,000 Not Implemented
AR0014 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $5,187 $2,889 Not Implemented
SD0069 # 07 Y:1993 07 1993 USE OPTIMUM THICKNESS INSULATION $381 $662 Implemented
SD0069 # 04 Y:1993 04 1993 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $35,110 $13,450 Not Implemented
UD0419 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $27,720 $60,000 Not Implemented
SF0015 # 05 Y:1993 05 1993 INSULATE BARE EQUIPMENT $1,767 $1,062 Implemented
IA0072 # 02 Y:1993 02 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $42,651 $56,888 Not Implemented
SF0015 # 07 Y:1993 07 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $1,416 $906 Implemented
IA0072 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $1,822 $7,616 Implemented
SD0069 # 05 Y:1993 05 1993 RECOVER WASTE HEAT FROM EQUIPMENT $41,306 $65,900 Not Implemented
SF0015 # 11 Y:1993 11 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $612 $162 Implemented
UD0419 # 03 Y:1993 03 1993 RECOVER WASTE HEAT FROM EQUIPMENT $3,741 $2,000 Not Implemented
AR0013 # 05 Y:1993 05 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,521 $8,400 Not Implemented
AS0105 # 09 Y:1993 09 1993 INSULATE BARE EQUIPMENT $1,707 $820 Implemented