Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

161

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0062 # 09 Y:1995 09 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,885 $587 Implemented
WV0066 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,127 $5,000 Implemented
KG0029 # 01 Y:1995 01 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $27,964 $682 Implemented
KG0029 # 02 Y:1995 02 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,307 $3,000 Implemented
HO0108 # 04 Y:1995 04 1995 KEEP BOILER TUBES CLEAN $1,420 $2,000 Implemented
UF0122 # 05 Y:1995 05 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $870 $1,000 Implemented
HO0102 # 04 Y:1995 04 1995 KEEP BOILER TUBES CLEAN $12,545 $1,000 Implemented
AR0054 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,281 $1,000 Implemented
SD0123 # 01 Y:1995 01 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,097 $1,939 Implemented
KG0027 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,341 $4,000 Implemented
MA0339 # 01 Y:1995 01 1995 BURN A LESS EXPENSIVE GRADE OF FUEL $4,128 $1,860 Implemented
HO0106 # 06 Y:1995 06 1995 KEEP BOILER TUBES CLEAN $1,072 $1,000 Implemented
ME0162 # 04 Y:1995 04 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $477 $400 Implemented
UD0461 # 01 Y:1995 01 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $28,758 $45,000 Implemented
UD0461 # 05 Y:1995 05 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,483 $1,000 Implemented
UL0127 # 02 Y:1995 02 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,913 $2,000 Implemented
MA0341 # 06 Y:1995 06 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $469 $400 Implemented
SD0121 # 04 Y:1995 04 1995 REDUCE EXCESSIVE BOILER BLOWDOWN $664 $15 Implemented
KU0456 # 03 Y:1995 03 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $292 $408 Implemented
ME0161 # 03 Y:1995 03 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,236 $400 Implemented
UD0459 # 05 Y:1995 05 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $545,061 $4,500,000 Implemented
UL0126 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $34,745 $2,000 Implemented
WV0062 # 01 Y:1995 01 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $12,196 $2,330 Implemented
OR0235 # 03 Y:1995 03 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $250 $500 Implemented
NC0055 # 01 Y:1995 01 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,521 $1,200 Implemented