Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,365

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0195 # 11 Y:1986 11 1986 INSTALL AUTOMATIC STACK DAMPER $456 $700 Implemented
GT0278 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,720 $500 Implemented
GT0279 # 04 Y:1986 04 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,140 $500 Implemented
GT0280 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,393 $700 Implemented
KU0191 # 05 Y:1986 05 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $525 $0 Implemented
LT0051 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,015 $0 Implemented
ST0051 # 05 Y:1986 05 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,847 $800 Not Implemented
ST0051 # 10 Y:1986 10 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,088 $1,200 Not Implemented
TS0033 # 06 Y:1986 06 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $922 $1,300 Not Implemented
CO0056 # 07 Y:1986 07 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $600 $1,200 Not Implemented
LT0051 # 03 Y:1986 03 1986 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,811 $8,000 Not Implemented
UD0187 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $509 $250 Implemented
UD0189 # 02 Y:1986 02 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $952 $0 Implemented
OK0186 # 06 Y:1986 06 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,479 $1,500 Not Implemented
MA0055 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,032 $1,000 Implemented
CO0054 # 05 Y:1986 05 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,210 $300 Implemented
CO0055 # 02 Y:1986 02 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,336 $300 Implemented
CO0054 # 06 Y:1986 06 1986 INSTALL TURBULATORS $674 $400 Implemented
KU0187 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $218 $0 Implemented
KU0189 # 02 Y:1986 02 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,071 $8,000 Implemented
KU0189 # 06 Y:1986 06 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $485 $0 Not Implemented
KU0187 # 02 Y:1986 02 1986 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $1,550 $2,000 Implemented
KU0189 # 03 Y:1986 03 1986 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $3,597 $500 Not Implemented
KU0187 # 04 Y:1986 04 1986 INSTALL AUTOMATIC STACK DAMPER $684 $1,200 Not Implemented
AT0034 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $4,201 $2,000 Implemented