Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

248

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0114 # 04 Y:1993 04 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,503 $4,500 Not Implemented
ME0114 # 05 Y:1993 05 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $597 $1,250 Not Implemented
NC0012 # 03 Y:1993 03 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,032 $4,500 Implemented
IA0068 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,707 $1,000 Implemented
IA0068 # 03 Y:1993 03 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,173 $1,364 Not Implemented
CO0287 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,360 $2,500 Not Implemented
AS0101 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $201 $500 Not Implemented
GT0501 # 02 Y:1993 02 1993 REDUCE EXCESSIVE BOILER BLOWDOWN $1,760 $0 Not Implemented
GT0501 # 01 Y:1993 01 1993 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $5,620 $10,000 Implemented
HO0058 # 05 Y:1993 05 1993 ADJUST BURNERS FOR EFFICIENT OPERATION $4,076 $1,600 Not Implemented
WI0190 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,245 $500 Implemented
CO0283 # 01 Y:1993 01 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $14,250 $36,500 Not Implemented
CO0282 # 02 Y:1993 02 1993 BURN A LESS EXPENSIVE GRADE OF FUEL $1,287,000 $325,000 Implemented
WV0015 # 06 Y:1993 06 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $8,836 $1,961 Implemented
IA0064 # 01 Y:1993 01 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $33,534 $4,388 Implemented
OR0184 # 01 Y:1993 01 1993 KEEP BOILER TUBES CLEAN $3,632 $500 Implemented
ND0155 # 05 Y:1993 05 1993 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $3,842 $40 Implemented
WV0014 # 06 Y:1993 06 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $90,331 $5,000 Implemented
SF0010 # 04 Y:1993 04 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $36,892 $31,700 Not Implemented
AS0097 # 10 Y:1993 10 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,151 $5,265 Not Implemented
KU0406 # 04 Y:1993 04 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $572 $489 Implemented
AS0097 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,546 $2,000 Not Implemented
ND0170 # 08 Y:1993 08 1993 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $307 $4,550 Not Implemented
TN0504 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,202 $1,500 Implemented
NC0007 # 08 Y:1993 08 1993 INSTALL TURBULATORS $8,700 $1,500 Implemented