Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

483

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0812 # 05 Y:2011 05 2011 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $13,390 $7,255 Not Implemented
OK0812 # 06 Y:2011 06 2011 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $12,936 $21,477 Not Implemented
OK0811 # 07 Y:2011 07 2011 RECOVER WASTE HEAT FROM EQUIPMENT $32,372 $270,346 Not Implemented
UD0839 # 06 Y:2011 06 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $80,401 $90,000 Not Implemented
UD0839 # 07 Y:2011 07 2011 USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) $29,882 $59,764 Not Implemented
UD0839 # 11 Y:2011 11 2011 REPAIR AND ELIMINATE STEAM LEAKS $5,425 $2,100 Implemented
UD0839 # 12 Y:2011 12 2011 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,987 $993 Implemented
SF0398 # 02 Y:2011 02 2011 REPAIR AND ELIMINATE STEAM LEAKS $4,412 $0 Implemented
SF0398 # 06 Y:2011 06 2011 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $136,531 $212,500 Not Implemented
GT0882 # 03 Y:2011 03 2011 UTILIZE A LESS EXPENSIVE COOLING METHOD $28,143 $70,000 Not Implemented
GT0882 # 08 Y:2011 08 2011 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $85,358 $222,000 Not Implemented
WV0428 # 01 Y:2011 01 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $74,991 $209,000 Not Implemented
WV0428 # 08 Y:2011 08 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,061 $8,550 Not Implemented
WV0428 # 11 Y:2011 11 2011 INSULATE BARE EQUIPMENT $5,623 $1,890 Not Implemented
UF0444 # 11 Y:2011 11 2011 COVER OPEN TANKS $9,431 $2,321 Not Implemented
SD0508 # 03 Y:2011 03 2011 REPAIR AND ELIMINATE STEAM LEAKS $2,193 $300 Implemented
TT0066 # 06 Y:2011 06 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $140 $30 Implemented
UD0838 # 09 Y:2011 09 2011 RECOVER WASTE HEAT FROM EQUIPMENT $7,585 $15,000 Not Implemented
UM0387 # 03 Y:2011 03 2011 RECOVER WASTE HEAT FROM EQUIPMENT $131,444 $85,000 Not Implemented
UM0387 # 04 Y:2011 04 2011 RECOVER WASTE HEAT FROM EQUIPMENT $57,295 $12,490 Not Implemented
UM0387 # 05 Y:2011 05 2011 RECOVER WASTE HEAT FROM EQUIPMENT $21,900 $55,250 Not Implemented
UA0061 # 04 Y:2011 04 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $98,700 $112,800 Not Implemented
GT0881 # 07 Y:2011 07 2011 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $38,551 $150,000 Not Implemented
WV0427 # 02 Y:2011 02 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,712 $42,275 Not Implemented
WV0427 # 03 Y:2011 03 2011 RECOVER WASTE HEAT FROM EQUIPMENT $8,998 $3,390 Not Implemented