Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,018
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0880 # 01 Y:2014 | 01 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $706 | $689 | Not Implemented |
OK0880 # 08 Y:2014 | 08 | 2014 | INSULATE BARE EQUIPMENT | $6,439 | $6,993 | Not Implemented |
OK0880 # 10 Y:2014 | 10 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $78 | $376 | Not Implemented |
MA0729 # 05 Y:2014 | 05 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,622 | $2,690 | Not Implemented |
LE0381 # 03 Y:2014 | 03 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $19,935 | $4,735 | Not Implemented |
LE0381 # 05 Y:2014 | 05 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $3,233 | $771 | Implemented |
LE0381 # 07 Y:2014 | 07 | 2014 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $9,549 | $5,000 | Not Implemented |
UD0902 # 10 Y:2014 | 10 | 2014 | INSULATE BARE EQUIPMENT | $348 | $0 | Not Implemented |
UM0444 # 04 Y:2014 | 04 | 2014 | USE MINIMUM STEAM OPERATING PRESSURE | $6,638 | $5,000 | Implemented |
TT0127 # 01 Y:2014 | 01 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $34,016 | $68,097 | Not Implemented |
WM0044 # 06 Y:2014 | 06 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $323 | $345 | Implemented |
NC0510 # 02 Y:2014 | 02 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,472 | $4,800 | Not Implemented |
NC0510 # 03 Y:2014 | 03 | 2014 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $1,500 | $1,000 | Implemented |
NC0510 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $39,042 | $3,000 | Not Implemented |
NC0510 # 05 Y:2014 | 05 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $26,718 | $67,500 | Implemented |
NC0510 # 06 Y:2014 | 06 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,896 | $1,750 | Not Implemented |
NC0510 # 14 Y:2014 | 14 | 2014 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,665 | $8,500 | Not Implemented |
AM0656 # 06 Y:2014 | 06 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $7,090 | $1,710 | Not Implemented |
OK0879 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,751 | $6,500 | Not Implemented |
OK0879 # 10 Y:2014 | 10 | 2014 | INSULATE BARE EQUIPMENT | $304 | $148 | Implemented |
SD0483 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $7,108 | $21,254 | Not Implemented |
SD0483 # 03 Y:2014 | 03 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,486 | $2,845 | Implemented |
UA0119 # 03 Y:2014 | 03 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,137 | $8,685 | Implemented |
IA0516 # 04 Y:2014 | 04 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,151 | $2,005 | Implemented |
UM0442 # 02 Y:2014 | 02 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $33,315 | $40,000 | Implemented |