Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

517

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0347 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,638 $8,898 Not Implemented
DL0028 # 02 Y:2008 02 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $47,800 $15,000 Implemented
DL0028 # 03 Y:2008 03 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $10,400 $5,000 Not Implemented
DL0028 # 01 Y:2008 01 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $122,000 $160,000 Not Implemented
DL0028 # 09 Y:2008 09 2008 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $1,400 $400 Implemented
UM0347 # 03 Y:2008 03 2008 COVER OPEN TANKS $2,233 $1,046 Not Implemented
DL0028 # 04 Y:2008 04 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $13,700 $3,000 Implemented
NC0384 # 05 Y:2008 05 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $1,068 $271 Implemented
NC0384 # 01 Y:2008 01 2008 RECOVER WASTE HEAT FROM EQUIPMENT $10,481 $5,000 Implemented
MS0335 # 02 Y:2008 02 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $24,959 $7,500 Not Implemented
MS0335 # 01 Y:2008 01 2008 REPAIR AND ELIMINATE STEAM LEAKS $38,137 $280 Not Implemented
SD0410 # 07 Y:2008 07 2008 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $22,978 $11,522 Not Implemented
SD0410 # 09 Y:2008 09 2008 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $10,867 $500 Not Implemented
WV0386 # 02 Y:2008 02 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $16,673 $8,525 Not Implemented
WV0386 # 04 Y:2008 04 2008 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $7,586 $8,100 Not Implemented
WV0386 # 03 Y:2008 03 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,988 $8,450 Not Implemented
WV0386 # 05 Y:2008 05 2008 INSULATE BARE EQUIPMENT $4,653 $920 Implemented
OR0540 # 02 Y:2008 02 2008 INCREASE AMOUNT OF CONDENSATE RETURNED $14,149 $6,100 Implemented
IC0149 # 09 Y:2008 09 2008 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $849 $0 Implemented
IC0149 # 04 Y:2008 04 2008 RECOVER WASTE HEAT FROM EQUIPMENT $3,526 $2,040 Implemented
MS0334 # 03 Y:2008 03 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $17,689 $11,700 Not Implemented
TT0010 # 02 Y:2008 02 2008 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $13,265 $26,530 Not Implemented
MS0333 # 07 Y:2008 07 2008 RECOVER WASTE HEAT FROM EQUIPMENT $1,170 $0 Not Implemented
WV0385 # 07 Y:2008 07 2008 INSULATE BARE EQUIPMENT $3,100 $140 Implemented
WV0385 # 14 Y:2008 14 2008 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $324 $50 Not Implemented