Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,028
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0844 # 10 Y:2007 | 10 | 2007 | INSULATE BARE EQUIPMENT | $10,329 | $19,630 | Not Implemented |
GT0844 # 11 Y:2007 | 11 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $26,394 | $20,000 | Not Implemented |
GT0844 # 12 Y:2007 | 12 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $136,209 | $66,970 | Not Implemented |
UM0331 # 03 Y:2007 | 03 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,277 | $4,600 | Not Implemented |
SD0400 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,093 | $7,520 | Not Implemented |
IA0415 # 07 Y:2007 | 07 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $84,655 | $36,000 | Not Implemented |
IA0415 # 08 Y:2007 | 08 | 2007 | INSULATE BARE EQUIPMENT | $525 | $635 | Implemented |
IA0415 # 09 Y:2007 | 09 | 2007 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,560 | $740 | Implemented |
IA0415 # 10 Y:2007 | 10 | 2007 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $2,038 | $2,236 | Implemented |
IA0415 # 11 Y:2007 | 11 | 2007 | INSULATE BARE EQUIPMENT | $2,180 | $1,563 | Not Implemented |
UM0330 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,750 | $12,000 | Not Implemented |
UM0330 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,366 | $5,250 | Not Implemented |
UM0330 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,228 | $4,500 | Not Implemented |
UM0330 # 08 Y:2007 | 08 | 2007 | COVER OPEN TANKS | $733 | $1,000 | Not Implemented |
UF0406 # 05 Y:2007 | 05 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $17,857 | $619 | Implemented |
UF0406 # 08 Y:2007 | 08 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,754 | $22,000 | Not Implemented |
UF0406 # 09 Y:2007 | 09 | 2007 | USE OPTIMUM THICKNESS INSULATION | $7,084 | $1,380 | Implemented |
UD0769 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,200 | $130,000 | Implemented |
UD0769 # 10 Y:2007 | 10 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $10,000 | $25,000 | Not Implemented |
IC0136 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,287 | $17,000 | Not Implemented |
MZ0016 # 03 Y:2007 | 03 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,312 | $3,000 | Not Implemented |
UM0329 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $154,115 | $300,000 | Not Implemented |
UM0329 # 02 Y:2007 | 02 | 2007 | COVER OPEN TANKS | $115,389 | $140,000 | Implemented |
UA0011 # 06 Y:2007 | 06 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,493 | $2,877 | Not Implemented |
UA0011 # 07 Y:2007 | 07 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,174 | $0 | Not Implemented |