Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,028

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0340 # 07 Y:2006 07 2006 RECOVER WASTE HEAT FROM EQUIPMENT $6,998 $0 Implemented
MA0608 # 07 Y:2006 07 2006 INSULATE BARE EQUIPMENT $1,575 $2,925 Implemented
SU0242 # 05 Y:2006 05 2006 INSULATE BARE EQUIPMENT $12,811 $4,204 Implemented
UD0750 # 09 Y:2006 09 2006 REPAIR AND ELIMINATE STEAM LEAKS $24,000 $13,000 Implemented
UD0750 # 01 Y:2006 01 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $273,386 $100,000 Not Implemented
UD0750 # 07 Y:2006 07 2006 USE OPTIMUM THICKNESS INSULATION $41,225 $39,892 Not Implemented
WI0522 # 03 Y:2006 03 2006 RECOVER WASTE HEAT FROM EQUIPMENT $12,607 $2,000 Implemented
UD0750 # 06 Y:2006 06 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $44,000 $25,000 Implemented
UD0750 # 03 Y:2006 03 2006 REPAIR OR REPLACE STEAM TRAPS $155,000 $187,200 Implemented
AM0516 # 04 Y:2006 04 2006 REPAIR AND ELIMINATE STEAM LEAKS $4,570 $1,000 Implemented
UD0749 # 07 Y:2006 07 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $111,197 $15,000 Not Implemented
UD0749 # 06 Y:2006 06 2006 MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS $127,000 $20,000 Not Implemented
UD0749 # 01 Y:2006 01 2006 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $973,467 $1,500,000 Not Implemented
UD0749 # 13 Y:2006 13 2006 USE MINIMUM SAFE OVEN VENTILATION $4,400 $0 Implemented
UD0749 # 04 Y:2006 04 2006 HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS $151,097 $0 Not Implemented
UF0389 # 04 Y:2006 04 2006 INSULATE BARE EQUIPMENT $18,625 $21,375 Not Implemented
UD0749 # 05 Y:2006 05 2006 INSULATE BARE EQUIPMENT $128,436 $44,181 Implemented
NC0344 # 01 Y:2006 01 2006 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $789,735 $918,265 Not Implemented
NC0344 # 03 Y:2006 03 2006 RECOVER WASTE HEAT FROM EQUIPMENT $48,795 $35,000 Not Implemented
NC0343 # 01 Y:2006 01 2006 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $137,000 $28,000 Not Implemented
UF0388 # 05 Y:2006 05 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $7,286 $1,238 Not Implemented
UF0388 # 07 Y:2006 07 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $193 $374 Not Implemented
UF0388 # 11 Y:2006 11 2006 PREHEAT COMBUSTION AIR WITH WASTE HEAT $12,667 $65,000 Not Implemented
AS0430 # 03 Y:2006 03 2006 INSULATE BARE EQUIPMENT $3 $1,077 Implemented
IA0394 # 06 Y:2006 06 2006 RECOVER WASTE HEAT FROM EQUIPMENT $16,584 $15,900 Not Implemented