IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,460

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0083 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $760 $3,900 Not Implemented
MA0573 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $2,868 $3,920 Implemented
NC0313 # 01 Y:2005 01 2005 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $9,148 $15,000 Not Implemented
NC0313 # 02 Y:2005 02 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $17,625 $50,000 Not Implemented
NC0313 # 04 Y:2005 04 2005 USE MINIMUM STEAM OPERATING PRESSURE $7,578 $200 Not Implemented
CO0562 # 04 Y:2005 04 2005 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $150 $120 Implemented
SU0208 # 06 Y:2005 06 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $137,714 $144,177 Implemented
NC0311 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $5,798 $14,107 Implemented
NC0311 # 05 Y:2005 05 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $4,051 $7,280 Not Implemented
BD0283 # 01 Y:2005 01 2005 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $5,694 $3,003 Implemented
BD0283 # 09 Y:2005 09 2005 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $352 $0 Implemented
LE0209 # 01 Y:2005 01 2005 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $669,800 $350,000 Not Implemented
LE0209 # 04 Y:2005 04 2005 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $10,145 $300 Not Implemented
IC0097 # 02 Y:2005 02 2005 ISOLATE HOT OR COLD EQUIPMENT $1,426 $3,768 Not Implemented
IC0097 # 05 Y:2005 05 2005 USE OPTIMUM TEMPERATURE $163 $1,044 Not Implemented
MS0271 # 01 Y:2005 01 2005 USE OPTIMUM THICKNESS INSULATION $46,503 $3,038 Not Implemented
CO0561 # 01 Y:2004 01 2004 RECOVER WASTE HEAT FROM EQUIPMENT $2,890 $4,100 Not Implemented
CO0561 # 04 Y:2004 04 2004 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $240 $480 Not Implemented
MA0572 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $15,571 $4,080 Implemented
MA0572 # 05 Y:2005 05 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,923 $3,540 Implemented
MA0572 # 07 Y:2005 07 2005 INSULATE BARE EQUIPMENT $1,200 $2,830 Implemented
MA0572 # 09 Y:2005 09 2005 REPAIR AND ELIMINATE STEAM LEAKS $160 $138 Implemented
WI0489 # 04 Y:2005 04 2005 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,606 $3,000 Not Implemented
UD0715 # 04 Y:2005 04 2005 REPAIR AND ELIMINATE STEAM LEAKS $2,597 $500 Implemented
AS0397 # 05 Y:2005 05 2005 INSULATE BARE EQUIPMENT $520 $250 Not Implemented