Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0410 # 05 Y:2002 05 2002 REPAIR AND ELIMINATE STEAM LEAKS $980 $250 Implemented
AM0410 # 02 Y:2002 02 2002 REPAIR OR REPLACE STEAM TRAPS $22,100 $580 Implemented
WV0231 # 06 Y:2002 06 2002 RECOVER WASTE HEAT FROM EQUIPMENT $1,704 $486 Not Implemented
WV0231 # 03 Y:2002 03 2002 INSULATE BARE EQUIPMENT $130 $384 Not Implemented
WV0231 # 05 Y:2002 05 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,374 $309 Not Implemented
MS0200 # 01 Y:2002 01 2002 PREHEAT COMBUSTION AIR WITH WASTE HEAT $22,848 $50,000 Not Implemented
OK0633 # 07 Y:2002 07 2002 INSTALL WASTE HEAT BOILER TO PRODUCE STEAM $752,359 $502,500 Implemented
UM0207 # 06 Y:2002 06 2002 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $560 $634 Not Implemented
OK0633 # 06 Y:2002 06 2002 OPTIMIZE OPERATION OF MULTI-STAGE VACUUM STEAM JETS $276,478 $200,000 Not Implemented
UD0636 # 09 Y:2002 09 2002 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $1,223 $0 Implemented
BD0202 # 02 Y:2002 02 2002 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $10,572 $25,000 Not Implemented
UD0636 # 03 Y:2002 03 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $20,230 $25,000 Implemented
UD0636 # 02 Y:2002 02 2002 INSULATE BARE EQUIPMENT $20,587 $7,200 Implemented
IC0027 # 06 Y:2002 06 2002 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $10,830 $33,832 Not Implemented
MS0199 # 01 Y:2002 01 2002 RECOVER WASTE HEAT FROM EQUIPMENT $7,110 $3,070 Not Implemented
AM0408 # 06 Y:2002 06 2002 INSULATE BARE EQUIPMENT $2,300 $1,335 Not Implemented
AM0408 # 08 Y:2002 08 2002 INSULATE BARE EQUIPMENT $500 $600 Implemented
SU0128 # 07 Y:2002 07 2002 INSULATE BARE EQUIPMENT $1,502 $1,100 Not Implemented
BD0201 # 09 Y:2002 09 2002 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $2,449 $11,500 Not Implemented
WV0230 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $4,650 $6,000 Not Implemented
WV0230 # 05 Y:2002 05 2002 RECOVER WASTE HEAT FROM EQUIPMENT $1,871 $620 Not Implemented
SU0127 # 02 Y:2002 02 2002 RECOVER WASTE HEAT FROM EQUIPMENT $1,022 $416 Not Implemented
TA0021 # 01 Y:2002 01 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $11,450 $5,883 Implemented
SU0127 # 03 Y:2002 03 2002 INSULATE BARE EQUIPMENT $781 $125 Not Implemented
TA0021 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $864 $504 Implemented