Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,000
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0213 # 02 Y:2001 | 02 | 2001 | INSULATE BARE EQUIPMENT | $19,198 | $3,152 | Not Implemented |
MA0485 # 07 Y:2001 | 07 | 2001 | INSULATE BARE EQUIPMENT | $2,300 | $10,000 | Implemented |
MA0485 # 09 Y:2001 | 09 | 2001 | INSULATE FEEDWATER TANK | $800 | $2,000 | Implemented |
MA0485 # 03 Y:2001 | 03 | 2001 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,000 | $12,000 | Implemented |
MA0485 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,000 | $40,000 | n/a |
SF0212 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $422 | $1,536 | Not Implemented |
WI0390 # 04 Y:2001 | 04 | 2001 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,118 | $6,350 | Not Implemented |
LE0102 # 01 Y:2001 | 01 | 2001 | COVER OPEN TANKS | $2,872 | $850 | Not Implemented |
MA0482 # 04 Y:2001 | 04 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,900 | $23,000 | Not Implemented |
NC0210 # 04 Y:2001 | 04 | 2001 | USE OPTIMUM THICKNESS INSULATION | $1,930 | $2,500 | Not Implemented |
LE0101 # 07 Y:2001 | 07 | 2001 | USE OPTIMUM THICKNESS INSULATION | $5,167 | $2,000 | Implemented |
LE0101 # 06 Y:2001 | 06 | 2001 | CLOSE OFF UNNEEDED STEAM LINES | $3,984 | $2,000 | Implemented |
LE0101 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $26,225 | $30,000 | Implemented |
AM0390 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,300 | $530 | Not Implemented |
UF0269 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $20,239 | $2,500 | Implemented |
AM0391 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $2,350 | $330 | Implemented |
SF0211 # 04 Y:2001 | 04 | 2001 | INSULATE BARE EQUIPMENT | $2,893 | $1,200 | Not Implemented |
SF0211 # 05 Y:2001 | 05 | 2001 | INSULATE BARE EQUIPMENT | $13,029 | $9,546 | Implemented |
SF0211 # 02 Y:2001 | 02 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $13,868 | $2,580 | Implemented |
SF0211 # 01 Y:2001 | 01 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $13,186 | $1,585 | Implemented |
MS0175 # 04 Y:2000 | 04 | 2000 | INSULATE BARE EQUIPMENT | $55 | $147 | Not Implemented |
GT0707 # 02 Y:2001 | 02 | 2001 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $6,057 | $5,500 | Not Implemented |
CO0481 # 06 Y:2001 | 06 | 2001 | USE OPTIMUM TEMPERATURE | $820 | $2,330 | Implemented |
WV0209 # 06 Y:2001 | 06 | 2001 | REDUCE EXCESS STEAM BLEEDING | $14,890 | $35,000 | Not Implemented |
CO0480 # 05 Y:2001 | 05 | 2001 | USE OPTIMUM TEMPERATURE | $610 | $200 | Not Implemented |