Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
592
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0730 # 04 Y:2005 | 04 | 2005 | COVER OPEN TANKS | $12,069 | $2,170 | Not Implemented |
UD0730 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,473 | $12,880 | Implemented |
UD0730 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $5,769 | $4,350 | Not Implemented |
UD0730 # 10 Y:2005 | 10 | 2005 | USE MINIMUM SAFE OVEN VENTILATION | $3,222 | $150 | Not Implemented |
UD0730 # 13 Y:2005 | 13 | 2005 | COVER OPEN TANKS | $315 | $0 | Not Implemented |
SU0221 # 08 Y:2005 | 08 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,125 | $5,000 | Not Implemented |
OR0489 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $1,800 | $2,100 | Implemented |
IC0109 # 02 Y:2005 | 02 | 2005 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $437,212 | $3,259,200 | Not Implemented |
IC0109 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,632 | $22,464 | Not Implemented |
IC0109 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $1,239 | $400 | Implemented |
IC0109 # 06 Y:2005 | 06 | 2005 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $37,809 | $131,160 | Not Implemented |
NC0323 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,020 | $3,726 | Not Implemented |
UD0729 # 10 Y:2005 | 10 | 2005 | INSULATE BARE EQUIPMENT | $487 | $0 | Implemented |
SF0314 # 02 Y:2005 | 02 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $6,788 | $0 | Implemented |
SF0314 # 04 Y:2005 | 04 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,926 | $807 | Not Implemented |
SU0220 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $47,114 | $10,000 | Implemented |
SU0220 # 07 Y:2005 | 07 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $8,034 | $2,780 | Implemented |
WV0326 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $6,011 | $1,797 | Implemented |
WV0326 # 08 Y:2005 | 08 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $652 | $367 | Implemented |
WV0326 # 07 Y:2005 | 07 | 2005 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $780 | $1,076 | Implemented |
WV0326 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,621 | $2,722 | Not Implemented |
AM0496 # 01 Y:2005 | 01 | 2005 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $35,000 | $102,400 | Not Implemented |
BD0293 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $824 | $2,100 | Implemented |
BD0295 # 01 Y:2005 | 01 | 2005 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $32,765 | $600 | Implemented |
BD0295 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $423 | $0 | Implemented |