Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,009
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1018 # 02 Y:2020 | 02 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,174 | $26,600 | Not Implemented |
UD1018 # 03 Y:2020 | 03 | 2020 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $25,124 | $0 | Not Implemented |
UD1018 # 08 Y:2020 | 08 | 2020 | INSULATE BARE EQUIPMENT | $359 | $392 | Not Implemented |
WM0160 # 01 Y:2020 | 01 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $142,628 | $60,000 | Not Implemented |
WM0160 # 08 Y:2020 | 08 | 2020 | INSULATE BARE EQUIPMENT | $261 | $657 | Not Implemented |
IP0138 # 04 Y:2020 | 04 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,110 | $4,000 | Not Implemented |
LE0497 # 06 Y:2020 | 06 | 2020 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $3,520 | $13,000 | Not Implemented |
MZ0295 # 09 Y:2020 | 09 | 2020 | INSTALL / REPAIR INSULATION ON STEAM LINES | $675 | $322 | Implemented |
MZ0295 # 10 Y:2020 | 10 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $2,456 | $9,000 | Not Implemented |
TR0027 # 01 Y:2020 | 01 | 2020 | USE OPTIMUM THICKNESS INSULATION | $5,150 | $2,324 | Implemented |
OK1028 # 02 Y:2020 | 02 | 2020 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,193 | $3,750 | Not Implemented |
OK1028 # 04 Y:2020 | 04 | 2020 | INSULATE BARE EQUIPMENT | $53 | $111 | Not Implemented |
UA0226 # 02 Y:2020 | 02 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,587 | $42,000 | Not Implemented |
BS0138 # 03 Y:2020 | 03 | 2020 | INSULATE BARE EQUIPMENT | $11,555 | $51,920 | Not Implemented |
MZ0293 # 07 Y:2020 | 07 | 2020 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $7,010 | $25,500 | Not Implemented |
MZ0293 # 09 Y:2020 | 09 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,186 | $28,360 | Not Implemented |
UF0551 # 03 Y:2020 | 03 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,520 | $30,000 | Implemented |
UF0551 # 07 Y:2020 | 07 | 2020 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,687 | $1,936 | Implemented |
WM0159 # 03 Y:2020 | 03 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $30,640 | $45,000 | Not Implemented |
IP0137 # 04 Y:2020 | 04 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,117 | $2,100 | Implemented |
DL0183 # 03 Y:2020 | 03 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,601 | $19,400 | Not Implemented |
GT0947 # 04 Y:2020 | 04 | 2020 | INSULATE BARE EQUIPMENT | $1,921 | $2,060 | Not Implemented |
AM0806 # 01 Y:2020 | 01 | 2020 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $49,500 | $85,000 | Not Implemented |
AM0806 # 04 Y:2020 | 04 | 2020 | INSULATE BARE EQUIPMENT | $5,470 | $3,350 | Implemented |
AM0807 # 03 Y:2020 | 03 | 2020 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,795 | $2,700 | Not Implemented |