Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

517

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0023 # 01 Y:2008 01 2008 INSULATE BARE EQUIPMENT $183 $80 Implemented
MZ0023 # 05 Y:2008 05 2008 REPAIR OR REPLACE STEAM TRAPS $47,858 $40,000 Implemented
LL0297 # 03 Y:2008 03 2008 REPAIR AND ELIMINATE STEAM LEAKS $4,566 $730 Implemented
LL0297 # 06 Y:2008 06 2008 INSULATE BARE EQUIPMENT $802 $930 Not Implemented
MS0330 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,490 $1,800 Implemented
MS0330 # 05 Y:2008 05 2008 REPAIR AND ELIMINATE STEAM LEAKS $2,517 $94 Not Implemented
UF0413 # 07 Y:2008 07 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $12,742 $20,000 Not Implemented
DL0015 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $20,000 $400 Not Implemented
DL0015 # 05 Y:2008 05 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $5,911 $2,500 Implemented
DL0015 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,000 $16,000 Not Implemented
DL0015 # 09 Y:2008 09 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $2,970 $10,000 Not Implemented
LL0296 # 05 Y:2008 05 2008 INSULATE BARE EQUIPMENT $4,739 $3,400 Not Implemented
SU0270 # 03 Y:2008 03 2008 REPAIR AND ELIMINATE STEAM LEAKS $48,133 $1,453 Implemented
SU0270 # 07 Y:2008 07 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $23,234 $18,896 Implemented
SU0270 # 08 Y:2008 08 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $392 $430 Implemented
MA0639 # 07 Y:2008 07 2008 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,426 $27,000 Implemented
MA0639 # 08 Y:2008 08 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $717 $1,000 Not Implemented
MI0168 # 01 Y:2008 01 2008 UTILIZE A LESS EXPENSIVE COOLING METHOD $256,906 $645,000 Not Implemented
IC0140 # 08 Y:2008 08 2008 USE OPTIMUM THICKNESS INSULATION $19,374 $4,100 Not Implemented
DL0018 # 01 Y:2008 01 2008 REPAIR AND ELIMINATE STEAM LEAKS $425,000 $120,000 Implemented
DL0018 # 03 Y:2008 03 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $188,000 $108,000 Implemented
DL0018 # 07 Y:2008 07 2008 RECOVER WASTE HEAT FROM EQUIPMENT $56,800 $129,000 Not Implemented
DL0018 # 08 Y:2008 08 2008 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $44,400 $35,000 Not Implemented
MA0640 # 03 Y:2008 03 2008 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $11,640 $43,000 Not Implemented
MA0640 # 07 Y:2008 07 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $644 $689 Implemented