IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,472

matching recommendations
Reset
ARC 2.24 HEAT RECOVERY
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0013 # 05 Y:1984 05 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,228 $3,000 Not Implemented
LT0007 # 05 Y:1984 05 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,375 $38,680 Not Implemented
TN0221 # 01 Y:1984 01 1984 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $4,406 $7,000 Not Implemented
TN0224 # 03 Y:1984 03 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,117 $3,860 Implemented
TN0224 # 06 Y:1984 06 1984 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $143 $150 Implemented
TS0007 # 01 Y:1984 01 1984 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $12,640 $34,000 Not Implemented
GT0226 # 03 Y:1984 03 1984 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $850 $2,300 Not Implemented
MA0007 # 02 Y:1984 02 1984 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $5,690 $3,000 Implemented
GT0229 # 02 Y:1984 02 1984 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $795 $1,000 Not Implemented
KU0141 # 03 Y:1984 03 1984 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $5,773 $14,000 Not Implemented
LT0011 # 06 Y:1984 06 1984 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $30,530 $69,200 Not Implemented
KU0139 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $1,988 $3,000 Not Implemented
KU0144 # 10 Y:1984 10 1984 RECOVER WASTE HEAT FROM EQUIPMENT $753 $400 Implemented
LT0011 # 04 Y:1984 04 1984 RECOVER WASTE HEAT FROM EQUIPMENT $799 $348 Not Implemented
CO0008 # 04 Y:1984 04 1984 RECOVER WASTE HEAT FROM EQUIPMENT $305 $200 Not Implemented
CO0010 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $472 $500 Not Implemented
GT0226 # 01 Y:1984 01 1984 RECOVER WASTE HEAT FROM EQUIPMENT $7,999 $10,000 Implemented
GT0232 # 05 Y:1984 05 1984 RECOVER WASTE HEAT FROM EQUIPMENT $1,370 $2,000 Implemented
ST0005 # 07 Y:1984 07 1984 RECOVER WASTE HEAT FROM EQUIPMENT $4,579 $268 Implemented
KU0140 # 15 Y:1984 15 1984 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $1,443 $500 Not Implemented
TN0221 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $1,248 $8,600 Not Implemented
UD0140 # 08 Y:1984 08 1984 RECOVER WASTE HEAT FROM EQUIPMENT $983 $1,500 Not Implemented
OK0152 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $196 $530 Implemented
ST0002 # 11 Y:1984 11 1984 RECOVER WASTE HEAT FROM EQUIPMENT $147 $370 Implemented
KU0132 # 09 Y:1984 09 1984 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,418 $1,110 Implemented