IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

73

matching recommendations
Reset
ARC 2.25 HEAT CONTAINMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0113 # 04 Y:1991 04 1991 COVER OPEN TANKS $506 $1,164 Implemented
KU0335 # 02 Y:1991 02 1991 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $6,430 $0 Implemented
MA0208 # 01 Y:1991 01 1991 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $5,634 $400 Implemented
OK0337 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $24,414 $1,184 Implemented
MO0021 # 06 Y:1991 06 1991 INSULATE BARE EQUIPMENT $1,577 $4,250 Implemented
MO0021 # 04 Y:1991 04 1991 INSULATE BARE EQUIPMENT $3,394 $6,952 Implemented
MA0208 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $4,350 $500 Implemented
CO0210 # 10 Y:1991 10 1991 INSULATE BARE EQUIPMENT $1,110 $1,180 Implemented
OR0110 # 01 Y:1991 01 1991 INSULATE BARE EQUIPMENT $102 $51 Implemented
TN0421 # 04 Y:1991 04 1991 COVER OPEN TANKS $944 $500 Implemented
OR0108 # 03 Y:1991 03 1991 INSULATE BARE EQUIPMENT $2,482 $4,030 Implemented
TN0421 # 01 Y:1991 01 1991 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $30,358 $17,288 Implemented
AM0111 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $6,300 $7,100 Implemented
CO0203 # 16 Y:1991 16 1991 INSULATE BARE EQUIPMENT $1,300 $1,800 Implemented
AM0111 # 05 Y:1991 05 1991 INSULATE BARE EQUIPMENT $1,820 $4,800 Implemented
AM0113 # 05 Y:1991 05 1991 INSULATE BARE EQUIPMENT $340 $290 Implemented
MA0202 # 03 Y:1991 03 1991 INSULATE BARE EQUIPMENT $196 $0 Implemented
AM0108 # 07 Y:1991 07 1991 INSULATE BARE EQUIPMENT $96 $426 Implemented
AS0016 # 05 Y:1991 05 1991 INSULATE BARE EQUIPMENT $8,146 $6,624 Implemented
WI0108 # 07 Y:1991 07 1991 INSULATE BARE EQUIPMENT $271 $117 Implemented
OK0333 # 04 Y:1991 04 1991 USE OPTIMUM THICKNESS INSULATION $4,914 $9,600 Implemented
TN0418 # 10 Y:1991 10 1991 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $69 $0 Implemented
TN0418 # 11 Y:1991 11 1991 INSULATE BARE EQUIPMENT $62 $146 Implemented