Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
14
matching recommendationsARC | 2.26 | COOLING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1515 # 07 Y:2015 | 07 | 2015 | CLEAN CONDENSER TUBES | $575 | $500 | Implemented |
IP0048 # 02 Y:2015 | 02 | 2015 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,379 | $5 | Implemented |
MI0284 # 01 Y:2015 | 01 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $77,529 | $180,000 | Implemented |
LE0401 # 11 Y:2015 | 11 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $5,980 | $15,100 | Implemented |
UD0933 # 05 Y:2015 | 05 | 2015 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,075 | $0 | Implemented |
IA0534 # 04 Y:2015 | 04 | 2015 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $590 | $2,620 | Implemented |
OK0916 # 03 Y:2015 | 03 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $30,382 | $0 | Implemented |
UM0458 # 01 Y:2015 | 01 | 2015 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $7,036 | $0 | Implemented |
UD0925 # 01 Y:2015 | 01 | 2015 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $860 | $0 | Implemented |
UM0455 # 04 Y:2015 | 04 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,274 | $7,300 | Implemented |
UD0924 # 12 Y:2015 | 12 | 2015 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,382 | $0 | Implemented |
CO0703 # 03 Y:2015 | 03 | 2015 | AVOID FROST FORMATION ON EVAPORATORS | $3,080 | $5,460 | Implemented |
LE0390 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $47,479 | $25,500 | Implemented |
MA0740 # 03 Y:2015 | 03 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,672 | $11,200 | Implemented |