IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

266

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0022 # 01 Y:1992 01 1992 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION $39,467 $20,000 Not Implemented
AS0058 # 07 Y:1992 07 1992 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $539 $114 Implemented
TN0465 # 02 Y:1992 02 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $817 $0 Not Implemented
TN0467 # 01 Y:1992 01 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $12,781 $0 Implemented
WI0151 # 02 Y:1992 02 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $783 $0 Not Implemented
WI0152 # 09 Y:1992 09 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,814 $0 Implemented
IA0021 # 06 Y:1992 06 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $20,195 $52,570 Not Implemented
MA0248 # 03 Y:1992 03 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,622 $1,872 Implemented
SD0024 # 07 Y:1992 07 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,811 $9,000 Implemented
UF0033 # 07 Y:1992 07 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $13,336 $7,000 Not Implemented
GT0466 # 05 Y:1992 05 1992 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $9,503 $50,000 Not Implemented
IA0021 # 07 Y:1992 07 1992 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $10,464 $2,700 Not Implemented
WI0152 # 07 Y:1992 07 1992 USE RADIANT HEATER FOR SPOT HEATING $9,809 $41,400 Not Implemented
UF0032 # 04 Y:1992 04 1992 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $474 $2,420 Not Implemented
UF0033 # 04 Y:1992 04 1992 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $14,800 $120,000 Not Implemented
UF0034 # 02 Y:1992 02 1992 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $11,737 $14,960 Not Implemented
UF0035 # 04 Y:1992 04 1992 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $136 $220 Not Implemented
AS0058 # 02 Y:1992 02 1992 USE HEAT PUMP FOR SPACE CONDITIONING $33,994 $182,325 Implemented
KU0374 # 03 Y:1992 03 1992 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,925 $4,800 Not Implemented
UF0034 # 05 Y:1992 05 1992 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $51,194 $68,400 Not Implemented
IA0018 # 02 Y:1992 02 1992 INSTALL TIMERS AND/OR THERMOSTATS $2,727 $1,000 Not Implemented
KU0372 # 12 Y:1992 12 1992 INSTALL TIMERS AND/OR THERMOSTATS $4,086 $0 Not Implemented
KU0373 # 02 Y:1992 02 1992 INSTALL TIMERS AND/OR THERMOSTATS $793 $935 Not Implemented
KU0374 # 02 Y:1992 02 1992 INSTALL TIMERS AND/OR THERMOSTATS $2,477 $0 Implemented
ND0023 # 05 Y:1992 05 1992 INSTALL TIMERS AND/OR THERMOSTATS $2,729 $3,400 Implemented