Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
172
matching recommendationsARC | 2.72 | SPACE CONDITIONING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0459 # 03 Y:2018 | 03 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,682 | $13,900 | Not Implemented |
OK0995 # 05 Y:2018 | 05 | 2018 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,003 | $2,512 | Not Implemented |
LE0460 # 05 Y:2018 | 05 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,333 | $19,000 | Not Implemented |
AS0458 # 08 Y:2018 | 08 | 2018 | AIR CONDITION ONLY SPACE NECESSARY | $713 | $312 | Not Implemented |
LS1813 # 02 Y:2018 | 02 | 2018 | INSTALL TIMERS AND/OR THERMOSTATS | $1,597 | $225 | Not Implemented |
UK1805 # 06 Y:2018 | 06 | 2018 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $495 | $1,250 | n/a |
UF0519 # 01 Y:2018 | 01 | 2018 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $27,363 | $868 | Implemented |
UF0519 # 03 Y:2018 | 03 | 2018 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $11,657 | $25,600 | Not Implemented |
UK1804 # 09 Y:2018 | 09 | 2018 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,112 | $1,500 | n/a |
NL0025 # 01 Y:2018 | 01 | 2018 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,194 | $15,000 | Not Implemented |
UK1804 # 15 Y:2018 | 15 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $681 | $0 | n/a |
AS0457 # 06 Y:2018 | 06 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,736 | $7,600 | Not Implemented |
NL0024 # 02 Y:2018 | 02 | 2018 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,242 | $10,000 | Not Implemented |
GT0916 # 02 Y:2018 | 02 | 2018 | AIR CONDITION ONLY SPACE NECESSARY | $5,518 | $200 | Not Implemented |
SU0464 # 01 Y:2018 | 01 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,408 | $1,206 | Not Implemented |
SF0526 # 02 Y:2018 | 02 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,043 | $1,093 | Implemented |
MA0793 # 03 Y:2018 | 03 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,289 | $5,525 | Not Implemented |
IC0206 # 03 Y:2018 | 03 | 2018 | USE RADIANT HEATER FOR SPOT HEATING | $2,158 | $3,396 | Not Implemented |
LE0459 # 05 Y:2018 | 05 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,564 | $8,400 | Implemented |
SF0525 # 04 Y:2018 | 04 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,086 | $354 | Not Implemented |
SU0462 # 01 Y:2018 | 01 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $857 | $0 | Not Implemented |
AS0456 # 03 Y:2018 | 03 | 2018 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $46,649 | $220,160 | Not Implemented |
MI0339 # 05 Y:2018 | 05 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $47,520 | $480 | Not Implemented |
LE0458 # 02 Y:2018 | 02 | 2018 | INSTALL TIMERS AND/OR THERMOSTATS | $1,449 | $150 | Not Implemented |
MI0339 # 02 Y:2018 | 02 | 2018 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $279,023 | $250,000 | Not Implemented |