IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

196

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0815 # 05 Y:2005 05 2005 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $4,041 $1,500 Not Implemented
GT0815 # 03 Y:2005 03 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $62,800 $36,000 Not Implemented
OR0494 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $55,000 $3,100 Implemented
UU0089 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,700 $2,000 Implemented
IC0110 # 01 Y:2005 01 2005 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $106,617 $213,420 Implemented
IC0110 # 05 Y:2005 05 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $13,789 $3,500 Implemented
IC0110 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,956 $0 Implemented
SD0373 # 02 Y:2005 02 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,494 $3,900 Not Implemented
GT0814 # 02 Y:2005 02 2005 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $235,000 $20,000 Not Implemented
IA0377 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,352 $1,000 Implemented
IA0377 # 08 Y:2005 08 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,988 $5,000 Implemented
IA0377 # 12 Y:2005 12 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $5,934 $15,000 Not Implemented
MS0288 # 01 Y:2005 01 2005 REPLACE BOILER $67,669 $215,000 Implemented
AS0411 # 02 Y:2005 02 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $18,100 $1,500 Not Implemented
AS0410 # 01 Y:2005 01 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $7,503 $6,000 Not Implemented
UU0095 # 01 Y:2005 01 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,360 $2,000 Implemented
NC0328 # 02 Y:2005 02 2005 BURN A LESS EXPENSIVE GRADE OF FUEL $113,412 $10,000 Not Implemented
NC0328 # 01 Y:2005 01 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $8,068 $6,225 Not Implemented
UD0731 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $17,198 $0 Not Implemented
UD0731 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,130 $0 Not Implemented
SD0372 # 04 Y:2005 04 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,072 $11,250 Not Implemented
CO0577 # 03 Y:2005 03 2005 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $89,400 $41,000 Implemented
SU0222 # 05 Y:2005 05 2005 INSTALL TURBULATORS $2,357 $246 Implemented
SU0222 # 09 Y:2005 09 2005 KEEP BOILER TUBES CLEAN $1,689 $800 Not Implemented
WV0327 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,759 $1,000 Implemented