Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

121

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0338 # 05 Y:2009 05 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,926 $1,000 Not Implemented
UA0034 # 10 Y:2009 10 2009 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $3,885 $17,000 Not Implemented
GT0861 # 03 Y:2009 03 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $38,729 $40,000 Implemented
GT0861 # 01 Y:2009 01 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,115 $0 Not Implemented
MS0337 # 03 Y:2009 03 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $38,691 $2,000 Not Implemented
UA0033 # 04 Y:2009 04 2009 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $61,530 $16,083 Not Implemented
TT0031 # 04 Y:2009 04 2009 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $10,527 $36,300 Not Implemented
GT0860 # 07 Y:2009 07 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,199 $4,250 Not Implemented
OK0773 # 01 Y:2009 01 2009 OPERATE BOILERS ON HIGH FIRE SETTING $14,770 $22,000 Not Implemented
OK0772 # 05 Y:2009 05 2009 OPERATE BOILERS ON HIGH FIRE SETTING $4,261 $17,500 Implemented
AM0556 # 01 Y:2009 01 2009 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $110,800 $325,000 Not Implemented
SD0412 # 02 Y:2009 02 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $21,022 $10,000 Not Implemented
LE0283 # 21 Y:2009 21 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $608 $565 Not Implemented
LE0283 # 01 Y:2009 01 2009 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $48,061 $100,000 Not Implemented
LE0283 # 10 Y:2009 10 2009 REPLACE BOILER $19,000 $30,000 Not Implemented
UD0791 # 01 Y:2009 01 2009 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $180,324 $20,000 Implemented
UD0791 # 07 Y:2009 07 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $11,202 $336 Implemented
UW0023 # 04 Y:2009 04 2009 CONTROL PRESSURE ON STEAMER OPERATIONS $6,132 $0 Not Implemented
BD0354 # 08 Y:2009 08 2009 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $24,415 $0 Not Implemented
UW0023 # 03 Y:2009 03 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $7,267 $200,000 Implemented
UA0029 # 08 Y:2009 08 2009 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $7,112 $109 Not Implemented