Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,629

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0170 # 15 Y:1985 15 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $962 $400 Not Implemented
KU0171 # 10 Y:1985 10 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $196 $157 Not Implemented
TN0260 # 03 Y:1985 03 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $696 $200 Not Implemented
LT0025 # 02 Y:1985 02 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $537 $670 Implemented
ST0029 # 06 Y:1985 06 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $20,887 $49,937 Not Implemented
KU0163 # 03 Y:1985 03 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $461 $400 Implemented
KU0163 # 17 Y:1985 17 1985 INSTALL AUTOMATIC STACK DAMPER $363 $900 Implemented
KU0167 # 03 Y:1985 03 1985 INSTALL AUTOMATIC STACK DAMPER $1,057 $800 Implemented
LT0025 # 03 Y:1985 03 1985 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $6,134 $500 Implemented
LT0024 # 05 Y:1985 05 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,010 $300 Implemented
LT0026 # 03 Y:1985 03 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,340 $405 Implemented
ST0026 # 01 Y:1985 01 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $292 $60 Not Implemented
ST0027 # 05 Y:1985 05 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $158 $260 Not Implemented
TN0256 # 02 Y:1985 02 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,103 $74 Not Implemented
GT0263 # 06 Y:1985 06 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $21,300 $400 Implemented
ST0026 # 06 Y:1985 06 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $6,181 $0 Not Implemented
ST0026 # 10 Y:1985 10 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $155 $450 Not Implemented
KU0162 # 09 Y:1985 09 1985 INSTALL AUTOMATIC STACK DAMPER $405 $700 Not Implemented
KU0158 # 13 Y:1985 13 1985 INSTALL AUTOMATIC STACK DAMPER $903 $1,600 Implemented
KU0159 # 07 Y:1985 07 1985 INSTALL AUTOMATIC STACK DAMPER $572 $1,000 Not Implemented
ST0023 # 02 Y:1985 02 1985 INSTALL AUTOMATIC STACK DAMPER $8,365 $26,400 Not Implemented
ST0024 # 06 Y:1985 06 1985 INSTALL AUTOMATIC STACK DAMPER $200 $2,550 Not Implemented
CO0027 # 04 Y:1985 04 1985 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $698 $200 Implemented
UD0161 # 05 Y:1985 05 1985 INSTALL AUTOMATIC STACK DAMPER $9,744 $1,377 Not Implemented
LT0021 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $745 $1,752 Implemented