IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

18

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0034 # 04 Y:1992 04 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $34 $13 Not Implemented
SD0032 # 06 Y:1992 06 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $138 $374 Not Implemented
KU0384 # 03 Y:1992 03 1992 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $1,309 $2,000 Implemented
GT0473 # 06 Y:1992 06 1992 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $200 $1,015 Not Implemented
WI0156 # 06 Y:1992 06 1992 INSTALL AUTOMATIC STACK DAMPER $452 $500 Not Implemented
IA0026 # 03 Y:1992 03 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,634 $496 Not Implemented
KU0377 # 04 Y:1992 04 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $645 $1,847 Not Implemented
RU0153 # 09 Y:1992 09 1992 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $3,815 $0 Not Implemented
CO0247 # 05 Y:1992 05 1992 INSTALL AUTOMATIC STACK DAMPER $6,430 $6,000 Implemented
KU0374 # 05 Y:1992 05 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $602 $1,066 Implemented
SD0022 # 05 Y:1992 05 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $158 $138 Implemented
SD0023 # 04 Y:1992 04 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $490 $245 Not Implemented
WI0148 # 06 Y:1992 06 1992 INSTALL AUTOMATIC STACK DAMPER $547 $700 Not Implemented
MA0240 # 08 Y:1992 08 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,022 $2,200 Implemented
MO0051 # 07 Y:1992 07 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $43 $110 Implemented
WI0139 # 11 Y:1992 11 1992 INSTALL AUTOMATIC STACK DAMPER $847 $1,400 Not Implemented
SD0013 # 01 Y:1992 01 1992 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $3,322 $1,636 Not Implemented
WI0136 # 03 Y:1992 03 1992 INSTALL AUTOMATIC STACK DAMPER $3,416 $2,300 Implemented