Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,018
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0223 # 02 Y:2017 | 02 | 2017 | INSULATE BARE EQUIPMENT | $7,340 | $2,435 | Implemented |
IP0083 # 02 Y:2017 | 02 | 2017 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $15,779 | $5 | Not Implemented |
GT0896 # 01 Y:2017 | 01 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,852 | $90,000 | Not Implemented |
TT0192 # 02 Y:2017 | 02 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,730 | $18,400 | Implemented |
IP0083 # 05 Y:2017 | 05 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,472 | $1,434 | Not Implemented |
SF0500 # 01 Y:2017 | 01 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $161 | $294 | Implemented |
SD0544 # 05 Y:2017 | 05 | 2017 | ISOLATE HOT OR COLD EQUIPMENT | $5,008 | $2,160 | Not Implemented |
SD0544 # 08 Y:2017 | 08 | 2017 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $2,798 | $7,832 | Implemented |
IP0082 # 11 Y:2017 | 11 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,464 | $9,078 | Not Implemented |
IP0082 # 08 Y:2017 | 08 | 2017 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $31,824 | $38,940 | Not Implemented |
TT0186 # 04 Y:2017 | 04 | 2017 | REDUCE EXCESS STEAM BLEEDING | $38,730 | $4,000 | Not Implemented |
UU0116 # 02 Y:2017 | 02 | 2017 | USE OPTIMUM TEMPERATURE | $6,759 | $0 | Not Implemented |
UK1614 # 03 Y:2017 | 03 | 2017 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,324 | $4,351 | Not Implemented |
NC0588 # 01 Y:2017 | 01 | 2017 | INSULATE BARE EQUIPMENT | $24,750 | $80,000 | Not Implemented |
NC0588 # 02 Y:2017 | 02 | 2017 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,845 | $38,000 | Not Implemented |
NC0590 # 04 Y:2017 | 04 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,073 | $6,000 | Not Implemented |
MI0307 # 09 Y:2017 | 09 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,516 | $8,584 | Not Implemented |
MI0307 # 02 Y:2017 | 02 | 2017 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $10,877 | $56,000 | Not Implemented |
IP0081 # 07 Y:2017 | 07 | 2017 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $1,643 | $1,949 | Not Implemented |
IP0081 # 10 Y:2017 | 10 | 2017 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $1,766 | $3,788 | Not Implemented |
LE0433 # 13 Y:2017 | 13 | 2017 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $53,347 | $200,000 | Not Implemented |
UM0485 # 04 Y:2017 | 04 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,035 | $2,500 | n/a |
UM0484 # 04 Y:2017 | 04 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $989 | $3,700 | n/a |
SD0540 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $17,767 | $20,883 | Not Implemented |
UK1613 # 03 Y:2017 | 03 | 2017 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,962 | $4,550 | Not Implemented |