Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

380

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0033 # 05 Y:2009 05 2009 INCREASE AMOUNT OF CONDENSATE RETURNED $7,848 $8,000 Not Implemented
NC0386 # 01 Y:2009 01 2009 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $31,742 $49,000 Not Implemented
NC0386 # 03 Y:2009 03 2009 RECOVER WASTE HEAT FROM EQUIPMENT $9,621 $3,300 Not Implemented
OR0544 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,500 $15,100 Not Implemented
NC0385 # 03 Y:2009 03 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,705 $1,900 Not Implemented
UD0791 # 02 Y:2009 02 2009 SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE $66,274 $0 Implemented
UD0791 # 06 Y:2009 06 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $11,734 $2,358 Not Implemented
UD0791 # 15 Y:2009 15 2009 CLOSE OFF UNNEEDED STEAM LINES $1,974 $1,100 Implemented
UA0031 # 07 Y:2009 07 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,782 $1,385 Not Implemented
UA0031 # 08 Y:2009 08 2009 INSULATE BARE EQUIPMENT $350 $610 Implemented
BD0354 # 07 Y:2009 07 2009 RECOVER WASTE HEAT FROM EQUIPMENT $13,322 $2,000 Not Implemented
TT0032 # 10 Y:2009 10 2009 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $865 $1,730 Not Implemented
UW0023 # 05 Y:2009 05 2009 RECOVER WASTE HEAT FROM EQUIPMENT $4,120 $60,200 Not Implemented
SF0369 # 02 Y:2009 02 2009 REPAIR AND ELIMINATE STEAM LEAKS $565 $60 Implemented
SF0369 # 04 Y:2009 04 2009 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $34,213 $37,500 Implemented
SF0369 # 05 Y:2009 05 2009 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $16,866 $26,548 Not Implemented
SF0369 # 06 Y:2009 06 2009 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $1,751 $3,312 Not Implemented
SF0369 # 08 Y:2009 08 2009 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $7,253 $41,149 Not Implemented
MA0643 # 01 Y:2009 01 2009 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $239,800 $170,000 Not Implemented
SU0275 # 03 Y:2009 03 2009 INSULATE BARE EQUIPMENT $2,108 $155 Implemented
SU0275 # 04 Y:2009 04 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $23,109 $11,160 Not Implemented
SU0276 # 05 Y:2009 05 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $5,842 $3,612 Not Implemented
UA0029 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $6,679 $2,900 Not Implemented
UA0030 # 04 Y:2009 04 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $60 $66 Not Implemented
UA0030 # 05 Y:2009 05 2009 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $174 $0 Implemented